Perlick F24N User Manual

Page of 8
Uncrating and Inspection
Remove all crating material before operating.
Carefully inspect cabinet for hidden damage. If
damage is discovered, file your claim immediately
with the transport company. Perlick is not 
responsible for damage in transit.
Plumbing
No plumbing connections are required. Condensate
from the cooling coil is automatically evaporated
through a condensate pan located in the 
condensing unit section.
Electrical
The cabinet must be connected to a separately
fused power source (see Electrical Specification
Plate) and grounded in accordance with National
and Local Electrical Codes. 
CAUTION: Do not attempt to operate the equipment
on any other power source than that listed on the
Electrical Specification Plate.
Placing the Cabinet
To assure maximum performance, fresh air must
be allowed to circulate through the machinery
compartment. Do not place anything in front of the 
cabinet that would obstruct air flow at these grilles.
Do not place the unit in an unventilated small room.
Cabinet should be leveled front to back and side 
to side.
Installing Casters or Legs 
(optional)
Attach casters or legs to the mounting bracket 
with the lockwashers and 
1
4
”–20 hex head nuts 
provided. Attach bracket and leg/caster assembly to
the side of the cabinet base using the  
1
4
”–20 hex
head self-tapping machine screws provided. 
Anti-tip 
(without Legs or casters)
To prevent the cabinet from tipping forward and to
provide a stable installation, the cabinet must be
secured in place with an anti-tip device.
A set of metal anti-tip brackets and installation
screws (#10-
3
4
” wood screws) are supplied. These
brackets should be attached to the floor, at the 
back of the cabinet; each bracket located to catch
each rear leveling leg when the cabinet is pushed
backward into position.
THE ANTI-TIP BRACKETS MUST CATCH EACH
OF THE LEVELING LEGS TO HAVE A STABLE
AND SAFE INSTALLATION.
Some installation sites might need to be modified to
provide a secure surface for attaching the bracket.
Refer to the illustration below for anti-tip mounting
bracket locations.
Sealing the Cabinet
For sanitation purposes, it may be necessary to
seal the base of the cabinet to the floor. This can be
accomplished by laying a bead of silicone sealant
between the base of the cabinet and the floor as
shown by the figure below.
When sealing the cabinet to the floor, make sure
that the louvered front grille plate can still be
removed for condenser maintenance and cleaning.
3
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Preparing the Cabinet – 
Single Door Freezer
Form No. Z2255
Rev. 08.22.06
1 1/2”
20 7/8”
Cabinet must  
have at least  
5/16” clearance  
from floor to 
accomodate  
brackets.
NOTE: Do not extend leveler leg
more than 3/4” out of base. Do not  
shim or pad to obtain levelness.
Shown with leg
leveler engaged
in anti-tip bracket.
Surface 
mounts
to floor.
Ø 3/8”
7/16”
TOP VIEW
BEAD SILICON
SEALER (RTV)
FLOOR
CABINET