HFD, HFCF SERIES ELECTRIC FRYER 
HOBARTCORP                                                                                                              F-32964 Rev. C (May 2012) 
-23-
 
 
BOIL OUT PROCEDURE: 
 
Use the Boil Out By-Pass™ drain extension allowing the boil 
out solution to exit the fry tank without using the filtering 
system.  Do not allow water to run through the motor / pump.  
Drain the boil out solution into a bucket or place a hose on the 
end of the drain extension allowing the other end to flow into a 
floor drain.  In Fig. 6 the arrow is pointing to the drain 
extension.  It is threaded into the top coupling of the oil drain 
tube.  Drain extension needs to be only hand tightened. 
 
 
 
 
 
 
 
 
Boil Out By-Pass™ Extension Tube
 
    
Fig. 
6
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Standard 
Hose 
End      Drain 
Tube 
End 
 
 
 
THERMAL OVERLOAD PROTECTION BUTTON: 
 
The motor/pump supplied with the filtering system 
has a thermal overload protection circuit that senses 
when excess heat occurs due to filtering for long 
periods of time or under heavy load prior to 
discarding debris buildup.  If the thermal overload 
protection is tripped, wait 5 minutes and then reset 
the motor by pushing in the red button.  The arrow in 
Figure 7 shows the location of the reset button; 
located on the front off the motor / pump facing 
towards you. 
 
 
 
 
 
 
Fig. 7