HFD, HFCF SERIES ELECTRIC FRYER 
HOBARTCORP                                                                                                              F-32964 Rev. C (May 2012) 
-24-
 
 
 
MAINTENANCE 
 
  
 
    Hot oil and hot parts can cause burns. Use care when operating, 
                          cleaning, and servicing the fryer. 
 
 
 
 
 
    Spilling hot fryer compound can cause severe burns.  Do not  
 
               move fryer without draining all frying compound from the tank.          
 
 
 
Service in the US and Canada 
 
Contact your local Hobart Service office or address on the front of this manual. 
 
In Australia 
 
Contact Hobart Food Equipment PTY. LTD., 16 Hilly Street Morlake, N.S.W. 2137 Australia; 
P.O. Box 100, Concord N.S.W. 2137; Tel: (02) 9736 1200; Fax: (02) 9736 1555.  
www.hobartfood.com.au
 
 
 
                                              
Troubleshooting Chart: 
 
Problem: 
    Probable 
Cause: 
 
No Heat: 
 
 
 
 
Power switch not turned on. 
      Wire 
connections 
loose 
(call 
service) 
      Wires 
connections 
need 
cleaning 
      High 
Limit 
(call 
service) 
 
Insufficient or too much heat: 
 
 
Temperature not set to desired temperature. 
      High 
limit 
tripped 
(call 
service) 
      Temperature 
probe 
(call 
service) 
 
 
 
 
 
 
 
Tank will not drain: 
 
 
 
Shortening too cold. 
      Drain 
pipe 
clogged 
with 
debris. 
 
Motor / pump will not pump oil:   
 
Suction tube not seated correctly in receptacle block. 
      Filter 
screen 
is 
clogged 
and 
needs 
cleaning. 
 
 
 
 
 
 
Shortening is too thick / cold.  Heat oil up to min. 300º F. 
 
 
 
 
 
 
Discard valve lever not fully engaged either for filtering or
 
 
 
 
 
 
discarding.