Frymaster M3000 User Manual

Page of 50
LOV
 Generation II Technical Reference
3
The ATO board is positioned under the LON gateway in a 
box with a transformer that provides power to the board. 
The LON gateway must be removed to access the ATO 
board.
The reservoir, or JIB, rests behind the right 
door of the fryer. A light on the front of the fryer 
illuminates when the jug is empty. 
Problem
Probable Causes
Corrective Action
Frypot tops off cold.
Incorrect setpoint.
Ensure setpoint is correct.
No power to ATO board.
A. J5 connection unplugged.
B. Fuse blown.
C. Transformer malfunction.
A. Check to ensure J5 on front of 
ATO board is fully locked into 
connector.
B. Ensure fuse below right control 
box is not blown.
C. Check that proper voltage is 
present at transformer.  See 
charts on pages 43-47.
The yellow JIB low light 
won’t illuminate.
A. Loose wire connection.
B. Power in the component box is not 
present.
C. Failed transformer.
A. Ensure the yellow LED is 
securely attached to plug J6 on 
the ATO board.
B. Ensure power is present in the 
component box.
C. If power is present in component 
box, check the transformer for 
correct voltage.
Troubleshooting the Top Off System
ATO Board
Transformer