2.7 Connection of Extensions
Installation Manual
137
2.7.2
Parallel Connection of the Extensions
Any SLT can be connected in parallel with an APT or a DPT as follows.
Note
In addition to an SLT, an answering machine, a fax machine or a modem (PC) can be connected in 
parallel with an APT or a DPT.
With APT
With DPT
Parallel mode or eXtra Device Port (XDP) mode can be selected through system programming.
Using a Modular T-Adaptor
To DHLC8 card
4-conductor wiring cord
Connect pins "T", "R", "D1",
and "D2".
2-conductor wiring cord
Connect pins "T" and "R".
SLT
APT
Modular
T-Adaptor
To DHLC8 card
SLT
DPT
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and 
"D2".
2-conductor wiring cord
Connect pins "T" and "R".