Smeg SA301X User Manual

Page of 20
Instructions for the installer
 
 
2. INSTALLATION 
 
2.1 Electrical connection 
 
Check that mains voltage and power cable ratings are as per the 
indications provided on the label attached to the oven door frame.  
This label must never be removed. 
 
 
 
It is obligatory for the electrical system to be grounded according to the 
methods required by safety rules. 
 
 
If a plug and socket connection is being used make sure that the plug 
and socket are compatible. Avoid use of adapters and shunts as these 
could cause overheating and risk of burns. 
 
 
If a fixed connection is being used fit power line with an omnipolar circuit 
breaker with a contact opening gap equal to or greater than 3 mm in an 
easily accessible position in proximity to the oven. 
 
 
 
 
 
For operation on 230-240V
: use an 
H05RR-F / H05RN-F / H05V2V2-F type 
three-core cable (3 x 1.5 mm
2
). 
 
The cable end to be connected to the 
appliance must be provided with an ground 
wire (yellow-green) at least 20 mm longer. 
 
 
 
 
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by non-observance of the above prescriptions or by 
interference with any part of the appliance. 
 
 
6