INSTALLATION 
 
• 
Note: The oven cavity must vent through the front only. Avoid gaps between the 
cavity sides and the underside of the worktop  
• 
Insert the oven into the cupboard. 
• 
Open the door to expose the fixing holes in the side trims.  
• 
Secure the oven by 4 countersunk screws (fasteners are not supplied). 
• 
The hob should be installed in a ventilated cupboard fitted with a sturdy worktop.  
• 
Secure the hob using the fixing brackets provided.
 
 
UNDER-COUNTER INSTALLATION 
for models 600S, ST (C optional)
 
 
Worktop 
32mm - 48mm thick
Vent 
gap
at
front
only
100
 590
 Aperture
 (210)
 Floor
Datum
900
 565         Aperture
Top filler piece
Typical section showing 
ventilation requirements
Aperture   
 590 H x 565 W x 570 D
6
 +
_30
 +
_30
 +
_30
 
 
UNDER-COUNTER INSTALLATION 
model 600STW
 
 
Worktop 
32mm - 48mm thick
For 32mm thick top
No filler piece will be 
required when a 
48mm thick top is used.
Datum
900
 565          Aperture
Top filler piece
Aperture   
 840 H x 565 W x 570 D
60
Vent 
gap
at
front
only
6
 +
_30
Levelling feet are provided to assist you in 
positioning the oven so that it stands firm 
and level. 
To adjust, tilt the oven back slightly and 
turn the relevant foot to either raise or lower 
the oven.