Hoshizaki KM-201BAH User Manual

Page of 81
17
  Fig. 
1      Fig. 
2
Freeze Timer (9 & 10)
Water Saver Timer (7 & 8)
Pump-Out Frequency Control 
(5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
S1 Dip Switch
S2 Dip Switch
Anti-Slush Control (5 & 6)
Float Switch Selector (2)
Pump-Out/Drain Selector (1)
b) Harvest Timer (S1 dip switch 1 & 2)
Used for adjustment of the harvest timer. The harvest timer starts counting when the 
thermistor reads a certain temperature at the evaporator outlet.
Dip Switch Setting
Time
(seconds)
No. 1
No. 2
OFF
OFF
60
ON
OFF
90
OFF
ON
120
ON
ON
180
c) Pump-Out Timer (S1 dip switch 3 & 4)
Once every ten freeze cycles, the drain valve opens to drain the water tank for the time 
determined by the pump-out timer. These switches also determine the time to delay 
completion of a defrost cycle, i.e. the minimum defrost time.
Do not change this setting, or the unit will not operate properly or produce high quality 
ice.
Dip Switch Setting
Time (seconds)
No. 3
No. 4
T1
T2
OFF
OFF
10
120
ON
OFF
10
180
OFF
ON
20
120
ON
ON
20
180
T1: Time to drain the water tank
T2: Harvest timer at pump-out
Refi ll Counter (3 & 4)
* Functions of S2 dip switch nos. 2 
through 6 depend on program version.