Hoshizaki KM-201BAH User Manual

Page of 81
42 
3. EVAPORATOR IS FROZEN UP 
 
PROBLEM POSSIBLE 
CAUSE 
REMEDY 
1. Leads shorted or 
defective switch. 
1. Check and replace. 
a) Float Switch 
2. Float does not move 
freely. 
2. Clean or replace. 
b) Inlet Water Valve 
1. Diaphragm does not 
close. 
1. Check for water leaks 
with icemaker off. 
Replace if necessary. 
[1] Freeze cycle 
time is too 
long. 
c) Control Board 
1. Defective. 
1. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
a) Evaporator 
1. Scaled up. 
1. Clean. 
b) Water Supply Line
1. Water pressure too low.
1. Check and get 
recommended pressure. 
1. Dirty mesh filter or 
orifice. 
1. Clean. 
c) Inlet Water Valve 
2. Diaphragm does not 
close. 
2. Check for water leaks 
with icemaker off. 
Replace if necessary. 
d) Ambient and/or 
water temperature
1. Too cool. 
1. Increase temperature. 
e) Thermistor 
1. Out of position or loose 
attachment. 
1. See “V. 17. 
THERMISTOR”. 
1. Harvest timer is set too 
short. 
1. Adjust longer, referring to 
“II. 4. THERMISTOR”. 
[2] All ice formed 
on Evaporator 
does not fall 
into bin in 
harvest cycle. 
f) Control Board 
2. Defective. 
2. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
1. Clogged. 
1. Clean. 
a) Spray Tubes 
2. Out of position. 
2. Place in position. 
b) Water System 
1. Dirty. 
1. Clean. 
c) Refrigerant 
1. Undercharged. 
1. Check for leaks and 
recharge. 
1. Bulb out of position or 
loose attachment. 
1. Place in position. 
d) Expansion Valve 
2. Defective. 
2. Replace. 
1. Coil winding opened. 
1. Replace. 
2. Plunger does not move.
2. Replace. 
e) Hot Gas Solenoid 
Valve 
3. Wiring to hot gas valve.
3. Check for loose 
connection or open, and 
replace. 
f) Water Supply Line
1. Too small; requires 9.5 
mm OD line dedicated 
per machine. 
1. Increase water supply line 
size. 
[3] Others 
g) Water Filter 
1. Flow rate too small. 
1. Replace with filter that 
has larger flow rate.