Hoshizaki KM-201BAH User Manual

Page of 81
53
Fig. 5
Remove Expansion 
Valve Cover fi rst
Cut ties to make Bulb 
removable
Bulb Insulation Hose
Expansion Valve
Bulb
7. AIR-COOLED CONDENSER
CAUTION
1. Always install a new drier every time the sealed refrigeration system is 
opened.
2. Do not replace the drier until after all other repair or replacement has 
been made. Install the new drier with the arrow on the drier in the 
direction of the refrigerant fl ow.
3. When brazing, protect the drier by using a wet cloth to prevent the drier 
from overheating. Do not allow the drier to exceed 250°F (121°C).
1) Unplug the icemaker or disconnect the power source.
2) Remove the panels.
3) Recover the refrigerant and store it in an approved container.
4) Disconnect the condenser inlet and outlet piping.
5) Remove the fan motor bracket from the condenser.
6) Remove the screws securing the condenser assembly, then remove the assembly.