I. Specifications
A. Icemaker
1. DCM-750BAH
Note: We reserve the right to make changes in specifications and design without prior 
notice.
AC SUPPLY VOLTAGE
115/60/1 
COMPRESSOR
120 V
13.2 RLA
   60 LRA
GEAR MOTOR
120 V
    3  FLA
  1/4 HP
FAN MOTOR
120 V
0.85  FLA
1/15 HP
AGITATING MOTOR
120 V
 1.8  FLA (Total)
 110 W
DISPENSING MOTOR
120 V
 0.9  FLA
   55 W
OTHER
120 V
 0.6  A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
    lbs./day ( kg/day )
70
*  803 (364)  770 (349)    726 (329)
    Reference without *marks
80
  684 (310)  645 (293)    608 (276)
90
  573 (260) * 567 (257)    509 (231)
100
  480 (218)  452 (205) *  423 (192)
SHAPE OF ICE
Cubelet (Compressed Flake Ice)
ICE QUALITY
Approx.  90%, Ice  (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
95 lbs.
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC    W  (kWH/100 lbs.)
1481 (6.3)
1449 (4.3)
    POTABLE WATER
68 (12)
96 (12)
             gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
34-1/16" x 28-1/2" x 48-1/16"  (865 x 723 x 1221 mm)
EXTERIOR FINISH
Stainless Steel; Galvanized Steel (Rear)
WEIGHT
Net 375 lbs. ( 170 kg ), Shipping 405 lbs. ( 184 kg )
CONNECTIONS - ELECTRIC
Permanent Connection
                           - WATER SUPPLY
Inlet 1/2" FPT
                           - DRAIN
Drain Pan 3/4" FPT
Bin Drain 3/4" FPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/4 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic,     Model RS55C2E-CAA-219
CONDENSER
Air-cooled, Fin and tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
1 lb. 7.1 oz. (660 g)
DESIGN PRESSURE
High 460 PSIG,  Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Auto-reset Overload Protector
GEAR MOTOR PROTECTION
Manual reset Circuit Breaker 
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES - SUPPLIED
Spare Fuse
                           - REQUIRED
Legs
OPERATING CONDITIONS
VOLTAGE RANGE
 104  -  127 V
AMBIENT TEMP.
   45  -  100° F
WATER SUPPLY TEMP.
   45  -   90° F
WATER SUPPLY PRESSURE
   10  -  113 PSIG