4. Electrical Connection
WARNING
This remote condenser unit requires a ground that meets the national and 
local electrical code requirements. To prevent possible electrical shock to 
individuals or extensive damage to equipment, install a proper ground wire to 
this condenser unit.
• This condenser unit must be connected to the fan motor junction box on the icemaker.
• The opening for the power supply connection is 7/8" DIA to fit a 1/" trade size conduit.
• Usually an electrical permit and services of a licensed electrician are required.
1) Remove the panel.
) Remove the junction box cover.
3) Connect the fan motor leads in the junction box of the remote condenser unit to the fan 
motor leads in the junction box of the HOSHIZAKI remote air-cooled icemaker.
4) Install a ground wire from the icemaker to the remote condenser unit.
5) Place the junction box cover and the louver panel in position.
Fig. 12
5. Stacking Condenser Unit
1) Secure the lower condenser unit to the legs with eight 
bolts (not included).
) Attach the upper condenser unit on the top of the lower.
3) Secure the upper condenser unit with the four screws 
provided.
4) Install refrigerant lines, and make electrical connection for 
each fan motor as shown in Items [c] and [d].
Fig. 13