Hoshizaki dcm-75ibah User Manual

Page of 61
54
Note: We reserve the right to make changes in specifications and design without prior 
notice.
AC SUPPLY VOLTAGE
115/60/1 
COMPRESSOR
115 V
   77 LRA
11.0 RLA
GEAR MOTOR
115 V
   3.0 FLA
1/4 HP
FAN MOTOR
115 V
   1.0 FLA
50 W
AGITATING MOTOR
120 V
   1.8 FLA (TOTAL)
110 W (TOTAL)
DISPENSING MOTOR
115 V
   0.9 FLA
55 W
OTHER
115 V
   0.6 A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
    lbs./day (kg/day)
70
*801 (363)
757 (343)
725 (329)
    Reference without *marks
80
695 (315)
666 (302)
639 (290)
90
612 (278)
*583 (265)
562 (255)
100
539 (245)
517 (234)
*490 (222)
SHAPE OF ICE
Cubelet
ICE HARDNESS FACTOR
90%  (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
95 lbs.
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC W (kWH/100 lbs.)
1388 (5.94)
1292 (4.08)
    POTABLE WATER
70 (12.0)
96 (12.0)
             gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
34-1/16" x 28-1/2" x 48-1/16"  (865 x 723 x 1221 mm) (No legs)
EXTERIOR FINISH
Stainless Steel; Galvanized Steel (Rear)
WEIGHT
Net 300 lbs. (136 kg), Shipping 345 lbs. (156 kg)
CONNECTIONS - ELECTRIC
Permanent Connection
                        - WATER SUPPLY
Inlet 1/2" FPT
                        - DRAIN
Drip Tray Drain Outlet 3/4" FPT
Storage Bin Drain Outlet 3/4" FPT
ICE MAKING SYSTEM
Auger Type
HARVESTING SYSTEM
Direct Driven Auger (1/4 HP Gear Motor)
ICE MAKING WATER CONTROL
Float Switch
DISPENSER CONTROL SYSTEM
Push Button
BIN CONTROL SYSTEM
Mechanical Bin Control and Timer
COMPRESSOR
Hermetic, Model RST61C1E-CFA-202
CONDENSER
Air-Cooled, Fin and Tube Type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A, 1 lb. 10 oz. (737 g)
DESIGN PRESSURE
High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Power Protect Relay
COMPRESSOR PROTECTION
Auto-Reset Internal Protector
GEAR MOTOR PROTECTION
Auto-Reset Internal Protector and Fuse (3A)
REFRIGERANT CIRCUIT PROTECTION
Auto-Reset High Pressure Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES - SUPPLIED
Spare Fuse (2-3A), Legs
                           - OPTIONAL
HS-5003, Apron kit when drip tray removed
OPERATING CONDITIONS
VOLTAGE RANGE
 104-127 V
AMBIENT TEMP.
   45-100° F
WATER SUPPLY TEMP.
   45-90° F
WATER SUPPLY PRESSURE
   10-113 PSIG
ENG F-013.0.1196
VIII. Technical Information
A. Specification Sheets
1. DCM-751BAH