APPROXIMATE
Ambient
ICE PRODUCTION
Temp.  (°F)
PER 24 HR.
70
800
363
779
353
758
344
80
738
335
719
326
700
317
90
681
309
685
311
646
293
lb./day   kg/day
100
629
285
612
278
563
255
APPROXIMATE ELECTRIC
70
1274
--
1275
--
1276
--
CONSUMPTION
80
1277
--
1278
--
1279
--
90
1280
--
1281
--
1284
--
watts
100
1286
--
1289
--
1291
--
APPROXIMATE WATER
70
474
1.79
513
1.94
686
2.60
CONSUMPTION PER 24 HR.
80
504
1.91
565
2.14
804
3.04
90
513
1.94
609
2.31
823
3.11
gal./day   l/day
100
623
2.36
659
2.49
1019
3.86
EVAPORATOR OUTLET TEMP.
70
12
-11
12
-11
12
-11
80
12
-11
12
-11
12
-11
90
12
-11
12
-11
13
-10
°F  °C
100
13
-10
13
-10
13
-10
HEAD PRESSURE
70
258
18.1
258
18.1
258
18.1
80
259
18.2
259
18.2
259
18.2
90
260
18.3
260
18.3
260
18.3
PSIG   kg/cm²G
100
257
18.1
257
18.1
257
18.1
SUCTION PRESSURE
70
32
2.3
32
2.3
32
2.3
80
33
2.3
33
2.3
33
2.3
90
33
2.3
33
2.3
33
2.3
PSIG   kg/cm²G
100
35
2.4
35
2.4
35
2.4
WATER FLOW FOR CONDENSER
20gal/h (AT 90°F /WT 70°F)
PRESSURE DROP OF COOLING WATER LINE
Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER
8,100 BTU/h  (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR
1,300 BTU/h  (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM GEAR MOTOR
700 BTU/h  (AT 90°F /WT 70°F)
Water Temp.  (°F)
50
70
90
2. DCM-751BWH(-OS)