17) Close the Cleaning Valve.
Note: The icemaker will not operate unless the Cleaning Valve is completely closed.
18) Replace the Front Panel in its correct position.
19) Turn on the power supply to fill the Water Tank with water.
20) Turn off the power supply after 3 minutes.
21) Remove the Front Panel, and fully open the Cleaning Valve.
22) Move the Control Switch to the “Wash” position.
23) Replace the Front Panel in its correct position.
24) Turn on the power supply to rinse off the cleaning solution.
25) Turn off the power supply after 5 minutes.
26) Remove the Front Panel and Insulation Panel.
27) Drain the Water Tank.  (See the above step 5.)
28) After the tank has drained, replace the removed parts in their correct positions.
Note:  Do not replace the Insulation Panel when you proceed to
                  “[b] SANITIZING PROCEDURE.’
29) Repeat the above steps 16) through 28) three more times to rinse thoroughly.
Note:  If you do not sanitize the icemaker, go to step 9) in “[b] SANITIZING
                 PROCEDURE.”
[b] SANITIZING PROCEDURE - Following Cleaning Procedure
1) Dilute a 5.25 % Sodium Hypochlorite solution (chlorine bleach) with water (Add 2.5
    fl. oz. of sanitizer to 5 gal. of water).
2) Remove the Insulation Panel, if it is in its normal position.
3) Pour the sanitizing solution into the Water Tank.