C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely 
affect performance and warranty coverage. For more information, contact your 
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions for both the "E" and "G" 
control boards:
a) "E" and "G" Control Board without Harvest Pump Timer Operation
Model
Auxiliary 
Code
Water Valve 
Part Number
Code on 
Water 
Valve 
S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-1601SWH/3
All
OFF OFF OFF OFF ON ON OFF OFF OFF ON
KM-1601SRH/3
R-0, R-1, 
some S-1
3U0111-02
(8 l/min)
J248-032
ON OFF ON OFF OFF OFF OFF OFF OFF OFF
Some S-1
3U0111-01
(15 l/min)
J248-030 
ON OFF OFF OFF ON ON OFF OFF OFF OFF
S-2 & later
4A1176-04 (11 l/min)
V-1 (M) & later
4A5251-04 (11 l/min)
KM-1900SAH/3  
KM-1900SWH/3
KM-2100SWH3  
KMH-2000SWH/3  
KMH-2000SRH3
All
OFF OFF OFF OFF OFF OFF OFF OFF ON OFF
KM-1900SRH/3  
KM-2100SRH3
All
ON OFF ON ON OFF OFF OFF OFF ON OFF
KM-2500S_H3
All
OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
KMH-2000SRH
All
OFF OFF OFF OFF OFF OFF OFF OFF ON ON