Hoshizaki SRH/3 User Manual
72
13. KM-1601SRH with URC-21F Auxiliary Codes: R-0, R-1, and some S-1
This data applies to units with an 8 l/min water valve. The 8 l/min water valve is part
number 3U0111-02 and has J248-032 stamped on the side of the valve facing the
rear of the unit.
number 3U0111-02 and has J248-032 stamped on the side of the valve facing the
rear of the unit.
SPECIFICATION SHEET
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with neutral for 115V)
AMPERAGE
12.8 A (5 Min. Freeze AT 104°F/WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2640(4.3)
2440(3.7)
WATER gal./24HR (gal./100 lbs.)
255(17.3)
503(31.8)
ICE PRODUCTION PER CYCLE
29.4 lbs. (13.3 kg) 1440 pcs.
TOTAL REFRIGERANT CHARGE
R404A, 24 lb. 14.6 oz. (11300g)
REFRIGERANT CHARGE BY UNIT
(Icemaker 15 lb. 3.4 oz. Cond. Unit 9 lb. 11.2 oz.)
PERFORMANCE DATA SHEET
70/21
1583
718
1550
703
1435
651
80/27
1558
707
1507
684
1353
614
90/32
1550
703
1472
668
1332
604
lbs./day kg./day
100/38
1503
682
1439
653
1203
546
70/21
80/27
90/32
watts
100/38
70/21
503
1.90
430
1.63
396
1.50
80/27
448
1.69
335
1.27
336
1.27
90/32
430
1.63
255
0.96
240
0.91
gal./day m3/day
100/38
348
1.32
251
0.95
226
0.86
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
201
14.1
215
15.1
235
16.5
80/27
211
14.9
233
16.4
254
17.8
90/32
215
15.1
248
17.4
269
18.9
PSIG kg/cm2G
100/38
219
15.4
253
17.8
288
20.2
70/21
36
2.5
38
2.7
41
2.9
80/27
38
2.6
41
2.9
44
3.1
90/32
38
2.7
43
3.0
47
3.3
PSIG kg/cm2G
100/38
39
2.7
44
3.1
50
3.5
CONDENSER VOLUME
441 CU. IN (URC-21F)
APPROXIMATE ICE
PRODUCTION PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
APPROXIMATE ELECTRIC
CONSUMPTION
2440
2499
2564
2485
2576
2633
2499
2640
2703
2507
2655
2760
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
22
23
26
23
25
28
23
26
29
24
27
31
HARVEST CYCLE TIME
6.7
5.7
5.4
5.9
4.3
4.6
5.7
3.2
3.2
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
4.6
3.2
3.2
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
24,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
ENG.F-011.1.0205