Hoshizaki C-100BAF-ADDS User Manual

Page of 44
38
VI. Cleaning and Maintenance
This icemaker must be cleaned and maintained in accordance with the instruction 
manual and labels provided with the icemaker. Consult with your local distributor 
about cleaning and maintenance service. To obtain the name and phone number of 
your local distributor, visit www.hoshizaki.com or call Hoshizaki Technical Support at 
1-800-233-1940 in the USA.
 WARNING
1. Only qualified service technicians should attempt to service this icemaker.
2. 
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews 
are securely in place after any cleaning or maintenance is done to the unit. 
Make sure that none have fallen into the storage bin.
3. The storage bin is for ice use only. Do not store anything else in the storage 
bin.
4. Keep the area around the icemaker clean. Dirt, dust, or insects in the unit 
could cause electrical damage to the equipment or harm to individuals.
5. Do not place fingers or any other objects into the ice discharge opening.
A. Cleaning and Sanitizing Instructions
Hoshizaki recommends cleaning and sanitizing this unit at least twice a year. More 
frequent cleaning and sanitizing, however, may be required in some existing water 
conditions.
 WARNING
1. To prevent injury to individuals and damage to the icemaker, do not use 
ammonia type cleaners.
2. Carefully follow any instructions provided with the bottles of cleaning and 
sanitizing solution.
3. Always wear liquid-proof gloves and goggles to prevent the cleaning and 
sanitizing solutions from coming into contact with skin or eyes.
4. Do not use ice made from the cleaning and sanitizing solutions. After cleaning 
and sanitizing, be careful not to leave any solution in the icemaker.
1. Cleaning Solution
IMPORTANT
For safety and maximum effectiveness, use the solution immediately after 
dilution.
Dilute 1.6 fl. oz. (47 ml or 3.2 tbs) of Hoshizaki "Scale Away" with 1 qt (1 l) of warm water. 
This is a minimum amount. Make more solution if necessary.
2. Cleaning Procedure
1) Move the power switch to the "OFF" position, then unplug the unit from the electrical 
outlet. 
2) Close the water supply line shut-off valve.