Hoshizaki DCM-500BWH User Manual

Page of 69
15
Microprocessor (board revision level 
indicated by last 2 digits on label)
"POWER" LED
(lights when 
power is supplied 
to the board)
"FLUSH" LED 
(X5 Relay)
Drain Valve
"COMP" LED 
(X2 Relay)
Compressor, 
Fan Motor
10.5V 
Transformer
"GM" LED 
(X1 Relay)
Gear Motor 
"DM" LED
(X4 Relay)
Shutter Solenoid, 
Dispensing Auger 
Motor
24V In
24V Supply Out
115V In
Gear Motor 
Protect Relay 
Circuit
Portion Control 
Timer
"AM" LED 
(X3 Relay)
Agitating Motor
Drain Valve 
24V Out
Dispensing Motor 
115V Out
Agitating Motor 
115V Out
115V In
Gear Motor 
115V Out 
115V In 
Counter Reset Button (not 
used in this application)
Control Board
Part Number 2A1592-01
1. Control Board Layout
a) DCM-500BAH, DCM-500BWH
Dispensing 
Components 
See "III.
B. Wiring 
Diagrams" 
for details.
Bin Control, 
Control 
Switch,
Low Water 
Safety
High 
Pressure 
Switch
Flush Switch 
Must be left in the "P" position, 
otherwise the internal drain 
timer will not operate.