I. Specifications
A. Icemaker
1. DCM-500BAH
Note: We reserve the right to make changes in specifications and design without prior 
notice.
AC SUPPLY VOLTAGE
115/60/1
COMPRESSOR
120 V
7.9 RLA
51 LRA
GEAR MOTOR
120 V
2.4 FLA
1/4 HP
FAN MOTOR
120 V
1.0 FLA
50 W
AGITATING MOTOR
120 V
0.9 FLA
55 W
DISPENSING MOTOR
120 V
0.9 FLA
55 W
OTHERS
120 V
0.2 A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp. (°F)
50
70
90
    lbs./day ( kg/day )
70
*535 (243)
510 (231)
485 (220)
Reference without * marks
80
461 (209)
438 (199)
416 (189)
90
396 (179)
*385 (175)
358 (162)
100
340 (154)
323 (147)
*304 (138)
SHAPE OF ICE
Cubelet (Compressed Flake Ice)
ICE QUALITY
Apprx. 90% Ice (90/70° F, CONDUCTIVITY 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
40 lbs.
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
    ELECTRIC    W  (kWH/100 lbs.)
1055 (6.6) 985 (4.4)
    POTABLE WATER
46 (11.9)
64 (11.9)
        gal./24HR    (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
26" x 22-1/2" x 40"   ( 661 x 571 x 1016 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
NET 251 lbs. (114 kg), Shipping 276 lbs. (125 kg)
CONNECTIONS - ELECTRIC
Permanent Connection
                      - WATER SUPPLY
Inlet       1/2" FPT
                      - DRAIN
Outlet    3/4" FPT x2
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/4 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model RS43C2E-CAA-219
CONDENSER
Air-cooled, Fin and tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R404A
1 lb 4.1 oz.  (570g)
DESIGN PRESSURE
High 460 PSIG
Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out Relay
COMPRESSOR PROTECTION
Auto-reset Overload Protector
GEAR MOTOR PROTECTION
Auto-reset Thermal Protector
Fuse
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES - SUPPLIED
Spare Fuse
                        - REQUIRED
Legs
OPERATING CONDITIONS
VOLTAGE RANGE
104-127 V
AMBIENT TEMP.
45-100 F
WATER SUPPLY TEMP.
45-90 F
WATER SUPPLY PRESSURE
10-113 PSIG
ENG F-013.0.1196