Hoshizaki DCM-500BWH User Manual

Page of 69
8
4. DCM-500BWH-OS
Note: We reserve the right to make changes in specifications and design without prior 
notice.
AC SUPPLY VOLTAGE
115/60/1
COMPRESSOR
120 V
7.9 RLA
51 LRA
GEAR MOTOR
120 V
1.6 FLA
1/6 HP
AGITATING MOTOR
120 V
0.9 FLA
55 W
DISPENSING MOTOR
120 V
0.9 FLA
55 W
OTHERS
120 V
0.2 A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
PER 24 HR.
Temp. (°F)
    lbs./day ( kg/day )
70
* 567 257 549 249 539 244
Reference without * marks
80
529 240 519 235 509 231
90
500 227 * 495 224 481 218
100
472 214 464 210 * 428 194
SHAPE OF ICE
Cubelet (Compressed Flake Ice)
ICE QUALITY
Approx. 89% Ice (90/70° F, CONDUCTIVITY 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
40 lbs.
ELECTRIC & WATER CONSUMPTION
90/70°F
    ELECTRIC    W  (kWH/100 lbs.)
930 (4.8)
    POTABLE WATER
56 (12)
WATER - COOLED CONDENSER
465 (100)
        gal./24HR    (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
26" x 22-1/2" x 40"   (661 x 571 x 1016 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 245 lbs. (111 kg), Shipping 269 lbs. (122 kg)
CONNECTIONS - ELECTRIC
Permanent Connection
                        - WATER SUPPLY
Inlet       1/2" FPT     Condenser Inlet  1/2"FPT
                        - DRAIN
Outlet    3/4" FPT x2 Condenser Outlet  3/8" FPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/6 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
Automatic Water Regulator
DISPENSE CONTROL SYSTEM
Photoelectric Sensor (Infrared)
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model RS43C2E-CAA-219
CONDENSER
Water Cooled, Double Tube Type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R404A
14.1 oz.  (400g)
DESIGN PRESSURE
High 460 PSIG
Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out Relay
COMPRESSOR PROTECTION
Auto-reset Overload Protector
GEAR MOTOR PROTECTION
Auto-reset Thermal Protector
Fuse
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES - SUPPLIED
Spare Fuse
                      - REQUIRED
Legs
OPERATING CONDITIONS
VOLTAGE RANGE
104-127 V
AMBIENT TEMP.
45-100°F
WATER SUPPLY TEMP.
45-90°F
WATER SUPPLY PRESSURE
10-113 PSIG
50
70
90
WATER TEMP. (°F)
70/50°F
985 (4.0)
65 (12)
285 (52)
ENG F-013.0.1196