2.  PERFORMANCE DATA
     DCM-270BAH (Air-cooled)
Note: Pressure data is recorded first 5 minutes in freezing cycle.  The data without *marks should be used
         for reference.
        We reserve the right to make changes in specifications and design without prior notice.
APPROXIMATE
Ambient
Water Temp.  (F)
ICE PRODUCTION
Temp.  (F)
PER 24 HR.
70
282
(128)
271
(123)
259
(118)
80
248
(113)
238
(108)
228
(103)
90
219
(99)
215
(98)
201
(91)
lbs./DAY  ( kg/day)
100
192
(87)
184
(84)
172
(78)
APPROXIMATE ELECTRIC
70
641
--
647
--
654
--
CONSUMPTION
80
660
--
667
--
673
--
90
680
--
686
--
690
--
watts
100
694
--
697
--
701
--
APPROXIMATE WATER
70
34
(128)
32
(123)
31
(118)
CONSUMPTION PER 24 HR.
80
30
(113)
29
(108)
27
(103)
90
26
(99)
26
(98)
24
(91)
gal. / day  (l/day)
100
23
(87)
22
(84)
21
(78)
EVAPORATOR OUTLET TEMP.
70
20
(-7)
20
(-7)
20
(-7)
°F  (°C)
80
20
(-7)
23
(-5)
23
(-5)
90
23
(-5)
23
(-5)
24
(-4)
100
24
(-4)
24
(-4)
24
(-4)
HEAD PRESSURE
70
217
(15.2)
217
(15.2)
217
(15.2)
80
251
(17.6)
251
(17.6)
251
(17.6)
90
285
(20.0)
285
(20.0)
285
(20.0)
PSIG (kg/sq.cmG)
100
327
(23.0)
327
(23.0)
327
(23.0)
SUCTION PRESSURE
70
37
(2.6)
37
(2.6)
37
(2.6)
PSIG (kg/sq.cmG)
80
40
(2.8)
40
(2.8)
40
(2.8)
90
43
(3.0)
43
(3.0)
43
(3.0)
100
46
(3.2)
46
(3.2)
46
(3.2)
TOTAL HEAT OF REJECTION
3532 BTU/h  (AT 90°F /WT 70°F)
50
70
90