Cornelius 3 User Manual

Page of 74
Viper Service Manual                                 
Publication Number: 621360041TBSER
- 62 -
© 2010, IMI Cornelius Inc.
C
ONTROL
 B
OARD
 R
EPLACEMENT
When replacing or testing electronic components, be sure to wear a static strap 
that is connected to a chassis ground. This protects the electronic components 
from any static charge while working on the unit.
The control board is located in the E-Box. It is mounted to the panel on four (4) 
plastic mounting studs, shown in Figure 55.
Figure 55. View of Control Board in E-Box
Software Compatibility
Fruitista sofware is not compatable with standard Viper sofware versions. When 
ordering replacement/service parts for any unit check the software version of the 
UI and IO boards and be sure to order the correct board.
Table 57
Step
Action
1
Disconnect power from the unit.
2
Connect a static strap to your wrist and any convenient chassis ground on the 
unit.
3
Unplug the eight (8) connectors from the control board.
4
Squeeze each of the mounting studs at the corners of the board while care-
fully lifting the board.
5
Replace the board with a new board.
6
Reverse the procedure to install the new board.
Mounting
Studs