ZyXEL Communications Vantage Access User Manual

Page of 620
 Chapter 11 Device Provisioning
Vantage Access User’s Guide
133
The following table describes the labels in this screen. 
"
Labels displayed in the Provision screens vary depending on settings in the 
InternetGatewayDevice field. 
Table 23   Provision > CPE Methods  
FIELD
DESCRIPTION
CPE 
Methods
Select SetParameterValues to change the value of the parameter on the device. 
Select GetParameterValues to obtain information of one or more parameters from the 
device. 
Select GetParameterNames to obtain the names of the parameter(s) on the device. 
Select SetParameterAttribute to change the settings of one or more parameters on the 
device. 
Select GetParameterAttribute to obtain information of one or more parameters from 
the device. 
Select AddObject to create a new instance of the selected parameter. 
Select DeleteObject to remove the specified instance of the selected parameter. 
Connection 
Request
Select this to have the device initiate a connection to Vantage Access immediately when 
Vantage Access requests. 
It is recommended to select this if you have disabled the Periodic Inform feature 
(PeriodicInformEnable=False) on the device. Otherwise, Vantage Access will fail to 
send any settings to the device. See 
NextLevel
This field displays when you select GetParameterNames in the CPE Methods field. 
Select this option to set the device to reply with a one-level (or relative) path for the 
parameter name. 
Clear this check box to set the device to reply with a complete (or full) path for the 
parameter name. 
Attribute
This field displays when you select SetParameterAttribute in the CPE Methods field. 
Select Active Notification to set the device to send a notification message to the 
Vantage Access server immediately when the value(s) of the parameter(s) is changed. 
Select Notification Off to set the device not to return a notification when the value(s) of 
the parameter(s) is changed. 
Select Passive Notification to set the device to send a notification message to the 
Vantage Access server in the next session when the value(s) of the parameter(s) is 
changed. 
Type
This field displays when you select SetParameterValues in the CPE Methods field. 
This read-only field displays the type and number of characters you can enter for the 
parameter value in the field below.
For example, string(256) indicates that you can enter up to 256 printable ASCII 
characters 
Value
Enter a new value for the parameter in this text box. 
MultiOperati
on
Select this if it is allowed to include multiple parameter settings in a provisioning packet. 
Select this to reduce the time for provisioning from Vantage Access to the device.
Otherwise, you can clear this to include only one parameter setting in a provisioning 
packet.
Back
Click Back to return to the previous screen. All unsaved changes will be lost. 
Apply Click 
Apply to save the changes. 
Reset
Click Reset to start configuring this screen again.