Troubleshooting Reference
No output voltage. The status LED is not 
lighting up.
The jumper wire on the power module 
panel connecting the “Ignition Control” 
and “Disabled” terminals is removed 
and there is no ignition signal present.
Ensure the jumper wire is installed if the ignition control feature 
is not in use. If the ignition control feature is in use, ensure the 
vehicle’s ignition is on.
The fan turns on and off during AC shore 
power mode.
The battery is discharged and 
demands high current from the 
charger.
AC pass-through current is high.
Do not be alarmed, the unit is performing normally.
The fan turns on and off during inverter 
mode.
The inverter is running continuously at 
high power.
Do not be alarmed, the unit is performing normally. The fan is 
activated automatically.
Table 8 Troubleshooting Reference