Xantrex Technology 806-1840 User Manual
44
Freedom HF Owner’s Guide
Specifications
NOTE: These specifications refer to inverter mode.
DC Input
1000-watt models
1500 and 1800-watt models
Operating voltage range for all models
10.5–15.5 VDC (low limit)
11.8–15.5 VDC (high limit)
11.8–15.5 VDC (high limit)
10.5–15.5 VDC (low limit)
11.8–15.5 VDC (high limit)
11.8–15.5 VDC (high limit)
Operating voltage range for Freedom HF 1500
and Freedom HF 1800 T
and Freedom HF 1800 T
n/a
10.5–15.5 VDC (low limit)
11.8–15.5 VDC (mid limit)
12.1–15.5 VDC (high limit)
11.8–15.5 VDC (mid limit)
12.1–15.5 VDC (high limit)
Safe non-operating voltage range
0–16 VDC
0–16 VDC
Nominal voltage for all models
12.5 VDC
12.5 VDC
Nominal current at full load
100 ADC
180 ADC
AC Output
1000-watt models
1500 and 1800-watt models
Output voltage
115 VAC
115 VAC
Continuous power
1.0kW @ 25 °C
1.8kW @ 25 °C
1.5kW @ 25 °C (Freedom HF 1500 only)
1.5kW @ 25 °C (Freedom HF 1500 only)
Surge power
17 AAC
(2kW for 200 ms)
(2kW for 200 ms)
30 AAC
(3.6kW for 300 ms)
(3.6kW for 300 ms)
Max short-circuit current
55 AAC peak
55 AAC peak
Frequency
60 Hz
60 Hz
Wave shape
Modified Sine Wave
Modified Sine Wave
Power derating above 40 °C ambient temp
Peak efficiency
87%
87%
Full load efficiency
80%
80%
Other
1000-watt models
1500 and 1800-watt models
No load input power (producing output voltage)
10W
10W
Off mode current draw
1mA
1mA
Freedom HF InvChg Owners Guide.book Page 44 Tuesday, April 29, 2014 12:10 PM