Moxa TCC-80 RS-232 - RS-422/485 Converter TCC 80 User Manual

Product codes
TCC 80
Page of 3
Industrial Networking Solutions
12-11
i n f o @ m o x a . c o m
w w w. m o x a . c o m         
Media Converters  
>
TCC-80
12
Port-powered RS-232 to RS-422/485 converter
External power source supported but not required 
 
Compact size 
 
Converts RS-422, and both 2-wire and 4-wire RS-485
 
RS-485 automatic data direction control 
 
Automatic baudrate detection 
 
15 KV serial ESD protection
 
Built-in 120-ohm termination resistors
 
The TCC-80 provides complete signal conversion between RS-232 and 
RS-422/485, without requiring an external power source. It supports 
both half duplex 2-wire RS-485 and full duplex 4-wire RS-422/485, 
either of which can be converted between RS-232’s TxD and RxD lines. 
In addition, the TCC-80’s 15 KV ESD protection guards against damage 
from electrostatic discharge.
The RS-232 port of the TCC-80 is a DB9 female socket that can 
connect directly to the host PC, with power drawn from the TxD, 
RTS, or DTR line. Regardless of whether the signal is high or low, 
the TCC-80 can obtain enough power from the data/handshake line. 
However, external power can be used if the handshake line is not 
available, if the serial cable is too long, or if the RS-232 device is a low 
power device. For external power, a 5 to 12 VDC power supply can be 
connected using an adaptor or a USB power cord.
Termination is a critical requirement for port-powered devices such as 
the TCC-80. In most circumstances, termination resistors are used if 
the RS-422/485 cable is longer than 100 m. Regardless of how much 
the data signal is dissipated, the termination resistors absorb more 
Introduction
Automatic data direction control is also provided for RS-485, in 
which the RS-485 driver is enabled automatically when the circuitry 
senses the TxD output from the RS-232 signal. This means that no 
programming effort is required to control the transmission direction of 
the RS-485 signal.
Port Power over RS-232
Optional External Power
External Power Adaptor
USB Power
than 75 mW of power. In other words, if long distance RS-422/485 
transmission or termination is required, then an external USB power 
cord or DC power supply should be used.
TCC-80
TCC-100: RS-232 to RS-422/485 converter
TCC-100I: RS-232 to RS-422 converter with optical isolation
TxD
RTS
DTR
Long Range/ 
Teminated 
RS-422/485 
Connection
´ xÊ6Ê̜ʴ£ÓÊ6 Ê
-iÀˆ>Ê-ˆ}˜>
,/-
,-‡{ÓÓÉ{nx
iۈViÃ
/,
/8
 
USB Port Power Cord
TxD
 RTS
DTR
Long Range/ 
Teminated 
RS-422/485 
Connection
The certifi cation logos shown here apply to some or all of the products in this 
section. Please see the Specifi cations section or Moxa’s website for details.