Beko CTB 6407 User Manual

Page of 16
 
 
 
 
 
EN 
6
 
Connections 
DUCTED VERSION AIR EXHAUST SYSTEM 
When installing the ducted version, connect the hood to 
the chimney using either a flexible or rigid pipe ø120 
mm, the choice of which is left to the installer. 
 
•  Fix the pipe in position using sufficient pipe clamps 
(not supplied). 
•  Remove any activated charcoal filters. 
 
ø 120
 
RECIRCULATION VERSION AIR OUTLET 
•  Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood. 
•  Connect the flange to the outlet on the shelf over the 
hood using a flexible or rigid pipe ø120 mm. 
•  Fix the pipe in position using sufficient pipe clamps 
(not supplied). 
•  Fix the directional grille 8 on the recirculation air 
outlet using the 2 screws 12e (2,9 x 9,5) provided. 
•  Ensure that the activated charcoal filters have been 
inserted. 
 
8
9
125
8
9
125
12e
 
ELECTRICAL CONNECTION 
•  Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 
mm. 
•  When opening the sliding carriage for the first time after installing the hood, pull it out 
briskly until it clicks.