INSTALLATION INSTRUCTIONS
Venting Options
General venting installation
For vented installations: 
Make necessary cuts in the wall for vent fittings. 
IMPORTANT: Make sure the vent system is installed before 
installing range hood.
Rrecirculating installations:
A vent system (not provided) that directs the recirculated air back 
into the room either through the soffit or through the cabinet top 
is required. Use Recirculation Kit Part Number 4396565. For 
ordering information, see “Assistance or Service.” 
IMPORTANT: If venting through the cabinet top, do not 
terminate the exhaust into dead air space such as an attic or 
enclosed soffit.
When venting through the soffit, assemble the vent system you 
will use over the exhaust collar, but do not attach the vent system 
yet.
NOTE: The vent system can exhaust out the front of the soffit or 
be rotated to exhaust out the side or end of the soffit.
Venting through the soffit
1. Assemble the vent system you will use over the exhaust 
collar, but do not attach the vent system yet.
NOTE: The vent system can exhaust out the front of the soffit 
or be rotated to exhaust out the side or end of the soffit.
2. Measure distance “A” (from top of hood to centerline of 
6" [15.2 cm] round vent). Mark the distance “A” on soffit.
3. Mark and cut a 6" (15.2 cm) round vent opening.
Venting through cabinet top
1. Mark the location where vent cover will be installed in the 
cabinet top and cut a 6" (15.2 cm) round vent opening for the 
vent cover.
IMPORTANT: Do not terminate exhaust into a dead air space 
such as an attic or enclosed soffit.
Prepare Location
For vented installations, it is recommended that the vent 
system be installed before hood is installed.
Do not cut a joist or stud unless absolutely necessary. If a 
joist or stud must be cut, then a supporting frame must be 
constructed.
Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for vent fittings.
Check that all the installation parts and the box with filters 
have been removed from the shipping carton.
Preparation
1. If possible, disconnect power and/or gas supply and move 
freestanding or slide-in range from cabinet opening to 
provide easier access to rear wall. 
A
A. Vent system
B. Vent cover
C. Cabinet top
D. Ceiling or soffit
E. Hood
A
B
C
D
E
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.