NuTone NP64000 User Manual

Page of 16
HL0070
- 3 -
RMP Series Backsplash
(Stainless Steel wall
covering with warming
shelves. Optional)
Model 418
10” round
adjustable elbow
(optional)
Model 412 
transition
(3
1
/
4
” x 10” to 7”)
Adapter and damper 3
1
/
4
” x 10”
(supplied with P5 blower)
Adapter and damper 3
1
/
4
’’ x 14’’
(supplied with P8 blower)
Standard duct
(3
1
/
4
” x 10”)
Duct
(3
1
/
4
” x 14”)
Model P5 
single-blower
(500 cfm)
NP64000 SERIES HOOD
NP64000 SERIES
RANGE HOOD SYSTEM -
INTERIOR BLOWERS
Flow deviator 
(vertical exhaust only) 
(supplied with P5 and P8 blowers)
Model 647
(7” Rd wall cap)
Model 634 or 644
(roof cap)
Model 643
(8” Rd wall cap)
8” round
standard
duct
Model 407 
(7” round - 
2 ft. sections)
Model 413 
transition
(3
1
/
4
” x 10” to 8”)
Model 459 transition
(3
1
/
4
” x 14” to 8”)
Model P8 dual-blower (900 cfm)
for use with 36’’ hoods or wider
NOTE: The dual blower P8 must be 
installed with 3
1
/
4
’’ x 14’’ duct. If it 
is impossible to connect the dual 
blower P8 to a 3
1
/
4
’’ x 14’’ duct, 
use a 3
1
/
4
’’ x 10’’ duct. In that 
case, the blower performance 
will be 25% decreased.
Rough-in kit 
(supplied with P5 and P8 blowers)
Model 415
7” round adjustable