Viking VIVC User Manual

Page of 4
VBCV Professional
Custom Wall
Ventilator System
VICV Professional
Custom Island
Ventilator System
DBCV Designer
Custom Wall
Ventilator System
DICV Designer
Custom Island
Ventilator System
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M
1 - 8 8 8 - V I K I N G 1
VENTILATION
Built-In Custom Ventilator Systems
Proper installation/ducting is extremely
important to ensure maximum
performance. Use a qualified and
trained installer.
DUCTING
• Check with a qualified and
trained installer or local codes
for makeup air requirements, if
any.
• Max. duct run length
o For 300 – 1,200 CFM—
50’ (152.4 m)
o For 1,500 CFM—75’ (22.9 m)
o Duct run length is for
general reference only;
always use a qualified and
trained installer.
o Straight runs and gradual
turns are best; for example,
each 90° elbow is equivalent
to 5’ – 10’ (1.52 – 3.05 cm)
of straight run.
• 7” (17.8 cm) round duct for
300 – 600 CFM; 10” for 900 –
1500 CFM
o Never use flexible duct; it
creates back pressure/air
turbulence and greatly
reduces performance.
GAS
Not applicable
ELECTRICAL
• Hardwire direct with two-wire
ground
• 120 VAC/60 Hz
• Max. amp usage (rating
includes recommended
ventilator kit rating)—see
Installation Requirements
table
PLUMBING
Not applicable
Installation Requirements
*1200 CFM interior and exterior (if applicable) ventilator should be used with all outdoor approved models and when indoor models are installed over
ranges/rangetops with gas grill.
**Must use 8” duct from canopy to ceiling – transition to 10” duct past duct cover.
Note: Exhaust capacity based on tests with 0.1 static pressure. Without applying static pressure (some brands do not), CFM could be
greatly overstated.
UTILITY REQUIREMENTS
R E L E A S E D 8 / 1 8 / 0 8
© 2 0 0 8 V R C — INFORMATION SUBJECT TO CHANGE
Model
Ventilator Kits
Interior
Exterior
Duct Size
Interior
Exterior/In-Line
Max. Amps
Interior
Exterior
VBCV3038
VIV300/600/1200*
VEV900/1200*
VIL900/1200*
7” (17.8 cm)/
10” (25.4 cm)
10” (25.4 cm)
5.0/6.2/8.7
8.7/6.1/3.0/4.8
VBCV3638
VIV300/600/1200*
VEV900/1200*
VIL900/1200*
7” (17.8 cm)/
VIL900/1200*
10” (25.4 cm)
5.0/6.2/8.7
8.7/6.1/3.0/4.8
VBCV4238
VIV600/1200*
VEV900/1200*
VIL900/1200*
7” (17.8 cm)/
VIL900/1200*
10” (25.4 cm)
6.2/8.7
8.7/6.1/3.0/4.8
VBCV4838
VIV1200*
VEV1200*/1500/VIL1200*
10” (25.4 cm)
10” (25.4 cm)
11.1
8.4/9.1/4.8
VBCV5438
VIV1200*
VEV1200*/1500/VIL1200*
10” (25.4 cm)
10” (25.4 cm)
11.1
8.4/9.1/4.8
VBCV6038
VIV1200*
VEV1200*/1500/VIL1200*
10” (25.4 cm)
10” (25.4 cm)
11.5
8.8/9.5/4.8
VBCV6638
VIV1200*
VEV1200*/1500/VIL1200*
10” (25.4 cm)
10” (25.4 cm)
11.5
8.8/9.5/4.8
VICV3698
VIV600/VIV1200*
VEV900/1200*/VIL900/VIL1200*
7” (17.8 cm)
10” (25.4 cm)
4.9/7.4
7.4/4.7/3.0/4.8
VICV4298
VIV600/1200*
VEV900/1200*/1500/
VIL900/VIL1200*
7” (17.8 cm)
10” (25.4 cm)
4.9
7.4/4.8/5.4/3.0/4.8
VICV5498
VIV1200*
VEV1200*/1500/VIL1200
10” (25.4 cm)
10” (25.4 cm)
8.2
5.6/6.2/4.8
VICV6698
VIV1200*
VEV1200*/1500/VIL1200
10” (25.4 cm)
10” (25.4 cm)
9.0
6.3/7.1/4.8
DBCV3082
DIV300/440
DEV900**/1200*/DIL900/DIL1200
7” (17.8 cm)
10” (25.4 cm)
1.7/3.2
6.6/3.9/3.0/4.8
DBCV3682
DIV300/440
DEV900**/1200*/DIL900/DIL1200
7” (17.8 cm)
10” (25.4 cm)
1.7/3.2
6.6/3.9/3.0/4.8
DBCV4282
DIV440
DEV900**/1200*/DIL900/DIL1200
7” (17.8 cm)
10” (25.4 cm)
3.2
6.6/3.9/3.0/4.8
DBCV4882
DIV880
DEV1200/1500/DIL1200*
10” (25.4 cm)
10” (25.4 cm)
5.6
4.3/5.1/4.8
DICV3632
DIV440
DEV900**/1200*
DIL900/DIL1200
7” (17.8 cm)
10” (25.4 cm)
4.0
7.5/5.2/3.0/4.8
DICV4232
DIV440
DEV900**/1200/1500
DIL900/DIL1200
7” (17.8 cm)
10” (25.4 cm)
4.0
7.5/5.2/6.0/3.0/4.8
DICV5432
DIV880
DEV1200/1500/DIL1200
10” (25.4 cm)
10” (25.4 cm)
6.4
5.2/6.0/4.8