Viking VIL1200 User Manual

Page of 4
CONNECTING DUCT WORK TO VIL1200 INLINE FAN
Two duct clamps part number 001377-000 are included 
with this unit and are intended to simplify fan installation 
and isolate fan vibration from the rigid metal duct.  
Note: The duct clamps are
convenient in installations 
where regular removal of the
fan in necessary for inspec-
tion and cleaning.
The built in hanger tab of the duct clamps are not intended to 
support the weight of the inline fan.  The inline fan should be 
supported with the integral brackets of the inline fans.
If special supports are required in anticipation of earthquakes 
the duct clamps that are supplied with the VIL1200 are not 
intended to meet these requirements.
To minimize vibration, leave a 1/4” gap between the inline fan 
collars and rigid duct.
Tighten the two screws until the fan and duct are snugly attached.
The duct work at the inlet of the inline fan is to be connected 
to the rough-in plate.
The duct work at the out box of the inline fan is to be con-
nected to a roof or wall cap.
A inline butterfl y damper part number PV300006 is included 
with  the  VIL1200.    The  damper  can  be  installed  anywhere 
in the duct system.  Damper must be installed so that the 
airfl ow direction will open the butterfl y blades.  Mounting the 
damper in an inverted position may prevent the blades from 
closing completely.  The preferred installation position is ver-
tical as shown below.
USE AND CARE
Disconnect electrical power supply and lock out service panel 
before cleaning or servicing this unit.
CLEANING
Periodic inspection and cleaning is recommended.  The fre-
quency of inspection and cleaning should be adjusted accord-
ing to the type and amount of cooking.
The interior of the fan can to accessed by removing the duct 
clamp and gently moving the duct work away from the inlet 
of the fan.
If excess build up is present it should be removed from the 
interior of the fan and from the impeller of the fan.
MOTOR LUBRICATION
The  motor  is  permanently  lubricated.    Do  not  oil  or  disas-
semble motor.
VIKING RANGE CORPORATION
GREENWOOD, MISSISSIPPI 38930 USA
4
RSK 
Damper
Duct 
Collar
Airfl ow 
Direction
ROUGH-IN 
PLATE
Damper
8mm
neoprene pad
Item #:450355
Date: 060707