Configuration
Setup Mode
1/7/10
Xi4™/RXi4™ User Guide
P1009874-002
Exit Setup Mode
When you exit setup mode, you have several options for saving, changing, or not changing 
parameters.
To leave Setup mode, complete these steps:
1.
While in Setup mode, press 
SETUP/EXIT
.
The LCD displays 
SAVE CHANGES
.
2.
Press 
PLUS (+)
 or 
MINUS (-)
 to display the save options:
3.
Press 
NEXT/SAVE 
to select the displayed choice.
When the configuration and calibration sequence is done, 
PRINTER READY
 displays.
LCD
Description
PERMANENT
Stores values in the printer even when power is turned off.
TEMPORARY
Saves the changes until power is turned off.
CANCEL
Cancels all changes made since you entered Setup mode, 
except for changes made to the darkness and tear-off settings, 
which go into effect as soon as they are made.
LOAD DEFAULTS
Restores all parameters other than the network settings back to 
the factory defaults. Use care when loading defaults because 
you will need to reload all settings that you changed manually.
Note • 
On non-RFID printers, loading factory defaults 
causes the printer to auto-calibrate.
LOAD LAST SAVE
Loads values from the last permanent save.
DEFAULT NET
Restores the wired and wireless network settings back to 
factory defaults.