Sub-Zero W362418(R) User Manual

Page of 8
Planning Information
Wolf Ventilation Recommendations
8
Dimensions in parentheses are in
millimeters unless otherwise specified.
P R O   V E N T I L A T I O N   C F M R E C O M M E N D A T I O N S
Pro 24" (610) Deep Wall Hoods
W302418
W362418
W422418
W482418
W542418
W602418
W662418
DF304 / R304 / SRT304
600
600
DF366 / R366 / SRT366 / RT366
900
900
DF364 / R364 / SRT364 / RT364
900
900
RT362
900
900
R488 / RT488
1100
1100
DF486 / R486 / SRT486 / RT486
1100
1100
DF484 / R484 / SRT484 / RT484
1100
1100
R482 / RT482
1100
1100
DF606 / R606
1500
1500
DF604 / R604
1500
1500
NOTE: For optimal performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a
charbroiler or griddle.
Model numbers for dual fuel ranges, gas ranges, sealed burner rangetops and gas rangetops indicate width and number of surface
burners. Features such as a charbroiler, griddle and/or French Top will vary.
CFM recommendations are based on total Btu/hr output. Wolf recommends 1 CFM per 100 Btu/hr (.03 kW). Additional CFM may be
required for long duct runs.
P R O   V E N T I L A T I O N   B L O W E R   O P T I O N S
Pro 24" (610) Deep Wall Hoods
Blower Description
Blower Number
Wall Hood Models
600 CFM Internal
WBLOWER-60INT (807614)
W302418 / W362418 / W422418
900 CFM Internal*
WBLOWER-90INT (805086)
W302418 / W362418 / W422418
1200 CFM Internal
WBLOWER-120INT (804702)
W482418 / W542418 / W602418 / W662418
600 CFM In-Line*
BLOWER-60IL (808331)
W302418
1100 CFM In-Line*
BLOWER-110IL (808332)
All 24" (610) Deep Wall Hoods
600 CFM Remote
BLOWER-60REM (801640)
W302418
900 CFM Remote
BLOWER-90REM (801641)
W302418 / W362418 / W422418 / W482418 / W542418
1200 CFM Remote
BLOWER-120REM (801642)
All 24" (610) Deep Wall Hoods
1500 CFM Remote
BLOWER-150REM (804701)
All 24" (610) Deep Wall Hoods
*Vertical discharge with 10" (254) round duct. All other blowers are adjustable discharge with 10" (254) round duct. NOTE: For optimal
performance, a Pro 27" (686) deep wall hood is recommended for use with ranges and rangetops that contain a charbroiler or griddle.
Wall hood models without decorative rail listed; blower options are the same for (R) models. Transition with backdraft damper included
with all wall hoods. Blower configurations are for reference only. Refer to minimum CFM recommendations for your specific cooking
product. Always consult a qualified HVAC Engineer for specific applications.