The Setup Menu Screen
AWG710&AWG710B Arbitrary Waveform Generator User Manual
3-51
Waveform, Pattern and Sequence Waveform Output
AWG710&AWG710B Arbitrary Waveform Generator waveforms can be output 
by selecting a waveform, pattern, or sequence file on the Setup menu screen and 
loading it into the waveform memory.
You may set the run and trigger modes and the output parameters such as the clock 
frequency, amplitude, offset an so on. Then, push the RUNCH1 OUT, and ALL 
MARKER OUT ON/OFF
 buttons on the front panel to output the waveforms in 
the waveform memory. A procedure to output the waveform is outlined below:
1. Push SETUP (front)!Waveform/Sequence (bottom)!Load... (side). 
Specify the file you want to output.
2. Push Run Mode (bottom)!Set the run mode in the side menu.
3. Push Trigger (bottom)!Set the trigger parameter in the side menu.
4. Push Vertical (bottom)!Set the vertical axis parameters, such as the 
amplitude, in the side menu.
5. Push Horizontal (bottom)!Set the horizontal axis parameters such as the 
clock frequency in the side menu.
6. Push the RUNOUTPUT, and ALL MARKER OUT ON/OFF buttons on 
the front panel.
Figure 3-7: Waveform output sequence example
During waveform output, you can make changes to an output parameter using the 
shortcut controls: VERTICAL LEVEL/SCALE, VERTICAL OFFSET, and 
HORIZONTAL SAMPLE RATE/SCALE.
Changes you make with the editor during waveform output are shown 
immediately. Refer to Edit...
 
on page 3-37.
Create and edit
waveform and
pattern sequence
Load waveform
and pattern
sequence
Set run and
trigger
modes
Set output
parameters
Push RUN and
OUTPUT buttons