Tektronix AWG710B User Manual
Waveform Mixing Mode
AWG710&AWG710B Arbitrary Waveform Generator User Manual
3-245
waveform or pattern file loaded in a waveform A or a waveform B. You cannot
view files other than waveform or pattern in this function. When you display a
mixed waveform on the screen, save it as a waveform file and open it on the
waveform editor.
view files other than waveform or pattern in this function. When you display a
mixed waveform on the screen, save it as a waveform file and open it on the
waveform editor.
Do the following steps to display a loaded file:
1. Push Waveform/Sequence (bottom)!View... (side)!View A or View B...
(side)
Waveform Mixing parameters
A mixed waveform is generated by the following formula to two specified
waveforms.
waveforms.
Mixed.wfm = A.wfm * Ratio of A + B.wfm * Ratio of B
Ratio of A...
Ratio of B...
Ratio of B...
The ratio of Waveforms A and B is specified with a Ratio of A and Ratio of B
button. The range of these parameters is as follows:
button. The range of these parameters is as follows:
0
≤
Ratio of A (%) + Ratio of B (%)
≤
100 (%)
1. Push Waveform/Sequence (bottom)!Setting... (side)!Ratio of A or Ratio
of B (side)
2. Use the general purpose knob, numeric buttons, or keyboard to change the ratio
of Waveform A and B.
Marker
This button lets you select which marker of Waveforms A or B is used as a marker
of a mixed waveform. The marker of the selected waveform is applied repeatedly
and let it be the marker of a mixed waveform until it fills the waveform length of a
mixed waveform.
of a mixed waveform. The marker of the selected waveform is applied repeatedly
and let it be the marker of a mixed waveform until it fills the waveform length of a
mixed waveform.
1. Push Waveform/Sequence (bottom)!Setting... (side)!Marker (side)
2. Push the Marker side button to toggle between Same as A and Same as B.
Wfm Len
This button lets you specify the length of a mixed waveform. It is specified from
the following:
the following:
Same as A: The number of points of a mixed waveform is made the same as
the number of points of Waveform A. When the number of points of Waveform
the number of points of Waveform A. When the number of points of Waveform