Delta Electronics SIG80M User Manual

Page of 4
 
 
                                                                                                                   
Page 1.
INSTALLATION AND OPERATING INSTRUCTIONS 
VENTILATION FAN / LIGHT / NIGHT LIGHT 
READ AND SAVE THESE INSTRUCTIONS   
GENERAL SAFETY INFORMATION
1.
Make sure that the electric service supply voltage is AC 
120V, 60Hz. 
2.
Follow all local electrical and safety codes, as well as the 
National Electrical Code  (NEC) and the Occupational 
Safety and Health Act (OSHA).   
3.
Always disconnect the power source before working on 
or near the ventilating fan, motor or junction box. 
4.
Protect the power cord from sharp edges, oil, grease, hot 
surfaces, chemicals or other objects. 
5.
Do not kink the power cord. 
6.
Do not install the unit where ducts are configured as 
shown in Fig. A. 
7.
Provide suction parts with proper ventilation. 
8.
This unit is UL listed for use over a bathtub or shower 
when installed in a GFCI protected branch circuit. 
9.
These ventilating fans are intended for residential usage 
only. 
WARNING 
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING: 
1.
Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer. 
2.
Before servicing or cleaning the unit, switch the power 
off on the service panel and lock the service 
disconnecting means to prevent power from being 
switched on accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel. 
3.
Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated construction. 
4.
Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent back drafting. Follow the 
heating equipment manufacturer’s guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society 
for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE) and local code authorities. 
5.
When cutting or drilling into the wall or ceiling, do not 
damage electrical wiring and other hidden utilities. 
6.
Ducted fans must always be vented to the outdoors. 
7.
If this unit will be installed over a tub or shower, it must 
be marked as appropriate for the application and be 
connected to a GFCI (Ground Fault Circuit Interrupter) – 
protected branch circuit. 
8.
Do not use this unit with any other solid-state control 
devices. Solid-state control devices may cause harmonic 
distortion, which can cause a motor humming noise. 
9.
NEVER place a switch where it can be reached from a tub 
or shower. 
10.
Turning angle too large
Duct shrink
y
d
o
b
 
e
h
r
a
e
n
 
w
o
b
l
E
s
w
o
b
l
e
 
y
n
a
m
 
o
o
T
Body
Fig. A 
CAUTION 
1.
For general ventilating use only. Do not use to exhaust 
hazardous or explosive materials and vapors. 
2.
Not for use in cooking areas. (Fig. B) 
3.
This product must properly connect to the grounding 
conductor of the supply circuit. 
4.
To reduce the risk of injury to persons, install the fan at 
least 7 feet (2.1m) above the floor. 
 
45
°
Cooking area
45
°
Do not install above or
  inside this area
 Cooking
Equipment
floor
 
Fig. B 
Not to be installed in a ceiling thermally insulated to a value 
greater than R40. (This is required for installation in Canada 
only).
MODELS SIG
80
 / SIG
80
M / SIG
110
 / SIG
110
D / SIG
110
H