Fujioh WS06 Leaflet

Page of 1
READ AND SAVE THESE INSTRUCTIONS.
FUJI INDUSTRIAL CO.,LTD .
Keep this manual in a convenient place for future reference.
www.fujioh.com
INSTALLATION MANUAL
WS06
FIG 2
1.
2.
3.
4.
   030984
WARNING
IMPORTANT
Connect the electrical wires in accordance with 
wiring diagram (figure 1).
Connect wires tightly and securely using wire 
connectors (not supplied).
Turn on the electrical circuit to the power unit. Check 
the ventilating functions at each speed control 
positions. Make sure that the range hood has no 
abnormal noises and/or vibration.
Your installation is now complete. 
If you should require service or replacement 
parts on your ventilation system. 
contact:
Fuji Industrial USA,Inc. 
16300 Christensen Rd, #212  Seattle, WA 98188
      1-888-547-9880
A 2-1/2" deep Wall Box must be used to allow space for 
wire connections between switch and 120 volt Power 
Input Leads.
Attach the wall plate, and secure with 2 screws. 
Electrical wiring should be done by a qualified person(s) 
in accordance with all applicable codes and standards, 
including fire-rated construction. An unqualified person 
doing the work could result in fire, electric shock or injury.
This switch uses 120 V AC, Max 16 Amp. Do not connect 
to other voltage or over current rate since fire, electric 
shock or damage could result.
Be sure to switch power OFF at service panel before 
wiring.
2-1/2" Deep Wall Box
(
must be grounded)
Bowers #52 or Equivalent
Motor Green or 
Bare Ground Wire 
- Grounded to 
Wall Box
From 
Blower Moter
< CONNECTING POWER SUPPLY WIRES >
FIG 1 < Connection Diagram >
Top
HI
OFF
LO
MED
Black
Ground
Neutral
Red
Blue
No Use
Switch:Red
Motor:Red
Low
Motor:Blue
Medium
Power Supply: White
M
GREEN/ GROUND
 WHITE
 /NEUTRAL
BLACK
/120V AC
GE Switch:
ASR-4173-500
(UL Recognized
Component)
Switch:Blue
Switch:Yellow
Power Supply Black
Switch:Black
Motor Black
High
Motor:White
Switch:  Blue 
Medium speed
Switch:  Red
Low speed
Switch:  Yellow
Switch: Black
High speed
Must use this wiring diagram for installation.
Do not use Thermador wiring diagram.