Honeywell VNT5200E1000 User Manual

Page of 68
Tools required to install ERV/HRV
 Aluminum foil tape (UL181B)
 Standard screwdriver
 Crescent wrench
 Hex driver (1/4 in.)
Accessories (not included)
 6 in. diameter insulated duct
 6 in. diameter duct
 Two 6 in. diameter weather hoods
E
F
D
OPTIONAL CONTROLS SOLD SEPARATELY
G
1
G
2
G
3
G
6
A
1
A
2
B
C
E
F
D
ERV/HRV VNT5150H1000 or VNT5150E1000 or
ERV/HRV VNT5200H1000 or VNT5200E1000
Heat/Energy Recovery Core (1)
Filter (2)
Professional Installation Guide
Duct Collars (4)
Installation Kit
Optional Controls: 1- Vision Pro IAQ, 2 - True IAQ,
3 - Dehumidistat H8908D, 4 - Prestige IAQ,
5 - 20/40/60 Minute Boost Control, and
6 - W8150 Ventilation Control
A
1
A
2
B
C
G
G
5
G
4
Tools required to install ERV/HRV
  Aluminum foil tape (UL181B)
  Standard screwdriver
  Crescent wrench
  Hex driver (1/4 in.)
Accessories (not included)
  6 in. diameter insulated duct
  6 in. diameter duct
  Two 6 in. diameter weather hoods
E
F
D
OPTIONAL CONTROLS SOLD SEPARATELY
G1
G2
G3
G6
A1
A2
B
C
E
F
D
ERV/HRV VNT5150H1000 or VNT5150E1000 or
ERV/HRV VNT5200H1000 or VNT5200E1000
Heat/Energy Recovery Core (1)
Filter (2)
Professional Installation Guide
Duct Collars (4)
Installation Kit
Optional Controls: 1- Vision Pro IAQ, 2 - True IAQ, 
3 - Dehumidistat H8908D, 4 - Prestige IAQ, 
5 - 20/40/60 Minute Boost Control, and 
6 - W8150 Ventilation Control
A1
A2
B
C
G
G5
G4
Tools required to install ERV/HRV
  Aluminum foil tape (UL181B)
  Standard screwdriver
  Crescent wrench
  Hex driver (1/4 in.)
Accessories (not included)
  6 in. diameter insulated duct
  6 in. diameter duct
  Two 6 in. diameter weather hoods
E
F
D
OPTIONAL CONTROLS SOLD SEPARATELY
G1
G2
G3
G6
A1
A2
B
C
E
F
D
ERV/HRV VNT5150H1000 or VNT5150E1000 or
ERV/HRV VNT5200H1000 or VNT5200E1000
Heat/Energy Recovery Core (1)
Filter (2)
Professional Installation Guide
Duct Collars (4)
Installation Kit
Optional Controls: 1- Vision Pro IAQ, 2 - True IAQ, 
3 - Dehumidistat H8908D, 4 - Prestige IAQ, 
5 - 20/40/60 Minute Boost Control, and 
6 - W8150 Ventilation Control
A1
A2
B
C
G
G5
G4
PROFESSIONAL INSTALLATION GUIDE
.
GUIDE D’INSTALLATION PROFESSIONNELLE
.
ERV/HRV Ventilation Systems
INCLUDED IN THIS BOX
69-2480EF-01
PROFESSIONAL INSTALLATION GUIDE
.
GUIDE D’INSTALLATION PROFESSIONNELLE
.
ERV/HRV Ventilation Systems
INCLUDED IN THIS BOX
69-2480EF-01
  
PROFESSIONAL INSTALLATION GUIDE
.
GUIDE D’INSTALLATION PROFESSIONNELLE
.
ERV/HRV Ventilation Systems
INCLUDED IN THIS BOX
69-2480EF-01

Summary of Contents of user manual for Honeywell VNT5200E1000

  • Page 1ERV/HRV Ventilation Systems PROFESSIONAL INSTALLATION GUIDE. GUIDE D’INSTALLATION PROFESSIONNELLE. INCLUDED IN THIS BOX A1 A2 B C G1 G2 G3...
  • Page 2: BenefitsInstallation Checklist Liste de vérification pour l’installation Included in This Box A1 ERV/HRV VNT5150H1000 or VNT5150E1000 or Contenu A2 ERV/HRV...
  • Page 3: Determining Your Ventilation NeedsERV/HRV Ventilation System ABOUT YOUR NEW VENTILATION SYSTEM INSTALLATION (continued) Benefits........................................................................ 2 Dehumidistat Wiring............................................. 23 Determining Your Ventilation Needs........................... 3...
  • Page 4: Specifications About the ERV/HRV Ventilation System The Honeywell ERV/HRV Ventilation System provides improved indoor air quality through its high performance...
  • Page 5Determining Your Ventilation Needs How much fresh air do you need? Good air quality is based in part on the...
  • Page 6 Specifications Dimensions in inches (mm): 2 1 1 FRONT CLEARANCE OF 25 INCHES H (635 MM) IS REQUIRED FOR...
  • Page 7Specifications (continued) VNT5150H1000 Ventilation Performance Gross Air Flow External Static Pressure Net Supply Air Flow Supply Exhaust Pa in. W.C....
  • Page 8 Specifications (continued) VNT5200H1000 Ventilation Performance External Static Gross Air Flow Net Supply Air Flow Pressure Supply Exhaust Pa in....
  • Page 9: External Control OptionsSpecifications (continued) VNT5150E1000 Ventilation Performance Gross Air Flow External Static Pressure Net Supply Air Flow Supply Exhaust Pa in. W.C....
  • Page 10: Install to Fit Your Application Specifications (continued) VNT5200E1000 Ventilation Performance External Static Gross Air Flow Net Supply Air Flow Pressure Supply Exhaust Pa in....
  • Page 11External Control Options The ERV/HRV unit may be used with one of the following external controls: Prestige™ (YTHX9321R5012) and Prestige™...
  • Page 12 Install to Fit Your Application NOTE: Prior to installing, serious consideration must be taken to insure this ventilation system...
  • Page 13: Installation StepsInstall to Fit Your Application (continued) B Exhaust at the Source and Supply in the Return STALE AIR FROM LIVING...
  • Page 14 Install to Fit Your Application (continued) C Exhaust and Supply in the Return 3 FEET 6 FEET TO LIVING...
  • Page 15Installation Steps 1 Installation Kit Ensure that you have all of the following installation items: 4 Duct Collars Installation Kit:...
  • Page 16 Installation Steps (continued) 3 Hanging the ERV/HRV The ERV/HRV unit enables you to save time and effort by offering...
  • Page 17Installation Steps (continued) Installing the flex duct to the ERV/HRV 4 TIP: Honeywell recommends using approximately 16 inches of flexible...
  • Page 18: Wiring Installation Steps (continued) Installing the condensation drain line 5 Insert the threaded drain adapter through the bottom of the...
  • Page 19: Prestige™ 2-wire IAQ and RF EIM WiringInstallation Steps (continued) 6 Connecting the power cord ERV/HRV Power Cord Insert the power cord on top of the unit....
  • Page 20: VisionPRO IAQ Wiring Automated Defrost The ERV and HRV units are equipped with an automatic defrost feature to eliminate any ice build...
  • Page 21: Forced Air SystemWiring (continued) Wiring with Remote Controls CONT mode - Ventilator runs continuously on low speed. A ventilation call from a...
  • Page 22: TrueIAQ (DG115EZIQ) Wiring Wiring (continued) Follow this diagram if using a Prestige™ Thermostat (Interlock not shown). PRESTIGE THEROMSTAT POWERED VENTILATOR NOT NOT...
  • Page 23: TimerWiring (continued) Follow this diagram for General Ventilator Wiring POWERED THERMOSTAT VENTILATOR VENTILATION CONTACTS C Y Y W W G...
  • Page 24: Control Panel Wiring (continued) Follow this diagram for Alternate Interlock Wiring with Forced Air System FAN TIMER OR OTHER POWERED WALL...
  • Page 25: Balancing StepsWiring (continued) Follow this diagram if using a Dehumidistat. M28994 EARD-6 AT120 Follow this diagram if using a W8150 Ventilation...
  • Page 26: Checkout Control Panel LED The control panel has a 3-position selector switch and “+” and “–” buttons for speed control....
  • Page 27: Periodic MaintenanceBalancing Steps NOTE: Perform the balancing steps with the HVAC equipment fan turned ON if the ERV/HRV unit is ducted...
  • Page 28: Cleaning Balancing Reset NOTE: Once balancing is completed, balancing cannot be changed without resetting the unit. LED To reset: Speed...
  • Page 29: TroubleshootingMaintenance Quarterly or as Needed Filters. 1 Four times per year or as needed, vacuum the filters. Replace filters as...
  • Page 30: Parts List Cleaning Steps 2. Open the side door panel by opening the two latches on the top of the side...
  • Page 31Troubleshooting CAUTION: Servicing the ERV/HRV unit with its electrical circuitry can cause personal injury. Always make sure that power to...
  • Page 32: 5-Year Limited Warranty Honeywell OS and Parts List Honeywell OS List Honeywell OS Number Controls Ventilator Type VNT5150H1000 No HRV VNT5150E1000 No...
  • Page 33Parts Illustration See the Parts List table on page 30 for items referenced by figure numbers 1 through 11 in...
  • Page 34: Avantages 5-Year Limited Warranty Honeywell warrants this product to be free from defects in the workmanship or materials, under normal...
  • Page 35: ventilationSystème de ventilation VRÉ/VRC À PROPOS DE VOTRE NOUVEAU SYSTÈME DE VENTILATION INSTALLATION (suite) Avantages.................................................................. 34 Câblage du Déshumidistat H8908D.......................
  • Page 36: Caractéristiques À propos du système de ventilation VRÉ/VRC Offrant une grande efficacité et un rendement élevé, le système de ventilation...
  • Page 37Établissement de vos besoins en matière de ventilation De quelle quantité d’air frais avez-vous besoin? Une bonne qualité d’air dépend...
  • Page 38 Caractéristiques Dimensions en mm (pouces) : 2 1 UN DÉGAGEMENT DE 635 MM 1 (25 PO) EST NÉCESSAIRE DEVANT...
  • Page 39Caractéristiques (suite) Performance du VNT5150H1000 en matière de ventilation Pression statique Débit d’air brut Débit d’air fourni net externe Débit...
  • Page 40 Caractéristiques (suite) Performance du VNT5200H1000 en matière de ventilation Pression statique Débit d’air brut Débit d’air fourni net externe...
  • Page 41: Commandes externes en optionCaractéristiques (suite) Performance du VNT5150E1000 en matière de ventilation Pression statique Débit d’air brut Débit d’air fourni net externe Débit...
  • Page 42: Installation selon votre utilisation Caractéristiques (suite) Performance du VNT5200E1000 en matière de ventilation Pression statique Débit d’air brut Débit d’air fourni net externe...
  • Page 43Commandes externes en option Le VRÉ/VRC peut être utilisé avec l’une des commandes externes suivantes : Prestige™ (YTHX9321R5012) et système...
  • Page 44 Installation selon votre utilisation REMARQUE : Avant l’installation du système de ventilation, il est important de s’assurer qu’il fonctionnera...
  • Page 45: Procédure d’installationInstallation selon votre utilisation (suite) B Évacuation dans la conduite d’entrée et apport dans la conduite de retour AIR VICIÉ...
  • Page 46 Installation selon votre utilisation (suite) C Installation selon votre utilisation (suite) pi) 91,44 cm (3 pi) 1,83 m (6...
  • Page 47Procédure d’installation 1 Trousse de quincaillerie Assurez-vous d’avoir les articles suivants en main avant d’installer le produit : 4 raccords...
  • Page 48 Procédure d’installation (suite) 3 Suspension du VRÉ/VRC Le système de suspension simplifié du VRÉ/VRC permet une installation rapide et...
  • Page 49Procédure d’installation (suite) Installation de la gaine flexible au VRÉ/VRC 4 CONSEIL : Honeywell recommande d’utiliser 40,64 cm (16 po)...
  • Page 50: Câblage Procédure d’installation (suite) Installation du tuyau d’évacuation des condensats 5 Insérez l’adaptateur de tuyau d’évacuation fileté sous l’appareil et...
  • Page 51: Prestige™ à deux filsProcédure d’installation (suite) 6 Branchement du cordon d’alimentation Cordon d’alimentation du VRÉ/VRC Insérez le cordon d’alimentation sur le dessus de...
  • Page 52: Câblage du VisionPRO IAQ Dégivrage automatique Les appareils VRÉ et VRC sont munis d’une fonction de dégivrage automatique afin d’éliminer la glace susceptible...
  • Page 53: VRÉ/VRC à un système à air pulséCâblage (suite) Câblage pour un fonctionnement avec commande à distance Mode CONT (continu) : le ventilateur fonctionne en continu à...
  • Page 54: TrueIAQ (DG115EZIQ) Câblage (suite) Suivez ce schéma si vous utilisez un ALIMENTATION thermostat Prestige™ DU VENTILATEUR (verrouillage non THERMOSTAT PRESTIGE représenté)....
  • Page 55: vitesse pour 20, 40 ou 60 minutesCâblage (suite) Suivez ce schéma pour ALIMENTATION le câblage général du DU VENTILATEUR ventilateur. THERMOSTAT CONTACTS DE VENTILATION C Y...
  • Page 56: Panneau de commande Câblage (suite) Suivez ce schéma pour l’autre option de raccord au système à ALIMENTATION air pulsé. MINUTERIE DU VENTILATEUR...
  • Page 57: Procédure d’équilibrageCâblage (suite) Suivez ce schéma si vous utilisez un déshumidistat. M28994 EARD-6 Suivez ce schéma si vous utilisez un régulateur...
  • Page 58: Vérification Panneau de commande DEL Le panneau de commande dispose d’un sélecteur Speed à trois positions et de boutons «...
  • Page 59: Entretien périodiqueProcédure d’équilibrage REMARQUE : Avant l’équilibrage, assurez-vous que le ventilateur du système CVCA est en marche (si l’appareil VRÉ/VRC est...
  • Page 60: Nettoyage Réinitialisation de l’équilibrage REMARQUE : L’appareil doit être réinitialisé avant chaque nouvelle procédure d’équilibrage. Réinitialisation : DEL 1. Appuyez...
  • Page 61: DépannageEntretien Aux trois mois (ou selon le besoin) Filtres. 1 Nettoyez les filtres à l’aide d’un aspirateur (quatre fois par...
  • Page 62: Liste des pièces Procédure d’entretien 2. Ouvrez le panneau de porte latérale en ouvrant les deux loquets situés en haut et en...
  • Page 63Dépannage MISE EN GARDE : L’entretien du VRÉ/VRC et de son système électrique peut entraîner des blessures. Assurez-vous que l’alimentation...
  • Page 64: Garantie limitée de 5 ans Honeywell : listes de modèles et de pièces Honeywell : liste de modèles Honeywell : numéro Numéro de Type...
  • Page 65Illustration des pièces Voir le tableau Liste des pièces à la page 30 : les articles sont référencés par numéros...
  • Page 6664 Systèmes de ventilation VRÉ/VRC 69-2480EF—01
  • Page 67Systèmes de ventilation VRÉ/VRC 69-2480EF—01 65
  • Page 68 Garantie limitée de 5 ans Honeywell garantit que ce produit ne présentera aucun défaut de matériaux ou de fabrication...