Motorola 700/800-Series User Manual

Page of 153
Set Environment to Bug/Operating System
A-11
A
Slave Ending Address #2
00000000
Ending address of the local resource that 
is accessible by the VMEbus. Default is 0. 
Slave Address Translation 
Address #2
00000000
Works the same as Slave Address 
Translation Address #1. Default is 0. 
Slave Address Translation 
Select #2
00000000
Works the same as Slave Address 
Translation Select #1. Default is 0. 
Slave Control #2
0000
DeÞnes the access restriction for the 
address space deÞned with this slave 
address decoder. Default is $0000. 
Master Enable #1 [Y/N]
Y
Yes, set up and enable the Master Address 
Decoder #1. 
Master Starting Address #1
02000000
Base address of the VMEbus resource that 
is accessible from the local bus. Default is 
the end of calculated local memory, 
unless memory is less than 16MB, then 
this register will always be set to 
01000000. 
Master Ending Address #1
EFFFFFFF
Ending address of the VMEbus resource 
that is accessible from the local bus. 
Default is the end of calculated memory. 
Master Control #1
0D
DeÞnes the access characteristics for the 
address space deÞned with this master 
address decoder. Default is $0D. 
Master Enable #2 [Y/N]
N
Do not set up and enable the Master 
Address Decoder #2. 
Master Starting Address #2
00000000
Base address of the VMEbus resource that 
is accessible from the local bus. Default is 
$00000000. 
Master Ending Address #2
00000000
Ending address of the VMEbus resource 
that is accessible from the local bus. 
Default is $00000000. 
Table A-1.  ENV Command Parameters (Continued)
ENV Parameter and Options
Default
Meaning of Default