Buffalo Technology TSXE80TLR5 User Manual

Page of 157
TeraStation User Manual
23
Using RAID 10 mode
Change system to normal mode (page 20).
Note: 
 After the RAID array is changed, the TeraStation will perfom a RAID check that will take about 5 hours per TB.  File 
transfers will be slower during this period.  While the “RAID ARRAY x Resyncing” message is displayed on the LCD 
screen, do not turn off the TeraStation. If you turn it off, the RAID check will start over.
 The [Confirm Operation] screen will appear.   
Enter the number shown in the [Confirmation Number] field within 60 seconds, and click [Apply].
Follow the instructions displayed on the screen.
You have now set up a RAID 10 array.  Turn to page 43 to create a shared folder.
Click the array you want to configure.
Select hard drives (all 4 of them) to use in RAID10.
Select [RAID 10].
Click [Create Raid Array].
Click [System] - [Storage] - [RAID Array] in the Web Admin interface.