Cold Drink Center (327/328) Operator’s Guide
3280020
Page 65
August, 2003
TEST THE SYRUP PUMPS
1.
Press 
, then press 
 until the display shows 
SYRUP TEST
 for a 
few moments.  The display will then show 
S.  
  
A number after the 
S. 
indicates a sold out condition on that pump.
2.
Press the number of the syrup pump you want to test.  Press the same 
number again to stop testing. A decimal will display whenever a pump is 
running.
NOTE
In a diaphragm pump machine, there are no sold out sensors, 
so the display only shows the pump number.  With gas pumps, 
the numbers  shown also reflect the sold out status.  However, 
status is only updated while dispensing.  Soldout status is 
"frozen" when dispensing stops.
3.
CONTINUE.
TEST THE ICE MAKER
1.
Press 
, then press 
 until the display shows 
ICE TEST
.
2.
Press 
 to dispense ice for about 1 second.  Press 
 to throw 
ice until 
 is pressed again.  The time delay (as described below) can 
be reset by dispensing ice for approximately 7 seconds.
NOTE
When the merchandiser is idle for an extended period of time, 
there is a software-controlled delay for replenishing ice to the 
ice maker.  This predetermined delay is initiated from the 
actuation of the low level hopper switch.  The delay is 
automatically reset during normal vending conditions.  For 
testing purposes, you can manually reset the delay:  Press and 
hold 
.  The display shows 
CLEARING
, then 
FINISHED
.
3.
CONTINUE.