Sun Microsystems 3900 Series User Manual

Page of 162
Chapter 8
Troubleshooting the Sun StorEdge T3+ Array Devices
107
For Internal Use Only
T1/T2 FRU Tests Available
Switch -
switchtest
Link -
linktest
Running
linktest
from the Storage Automated Diagnostic Environment GUI
will guide the Service Engineer to discover the failed FRU.
Once the test has completed its run, an email message, similar to the following
message, will be sent to the Email recipient that was specified in
linktest
.
FIGURE 8-4
Example Link Test Text Output from the Storage Automated Diagnostic
Environment
running on diag.xxxxx.xxx.com
 linktest started on FC interconnect: switch to switch
 switchtest started on switch 100000c0dd00b682 port 8
 Estimated test time 14 minute(s)
 01/30/02 11:21:26 diag209 Storage Automated Diagnostic Environment: MSGID
6013 switchtest.FATAL
 switch0: "Device: Switch Port: 8 is Offline"
 switchtest failed
 Remove FC Cable from switch: 100000c0dd00b682, port: 8
 Insert FC loopback cable into switch: 100000c0dd00b682, port: 8
 Continue Isolation ?
 switchtest started on switch 100000c0dd00b682 port 8
 Estimated test time 14 minute(s)
 01/30/02 11:22:11 diag209 Storage Automated Diagnostic Environment: MSGID
6013 switchtest.FATAL
 switch0: "Device: Switch Port: 8 is Offline"
 switchtest failed
 Remove FC loopback cable from switch: 100000c0dd00b682, port: 8
 Insert a NEW FC GBIC into switch: 100000c0dd00b682, port: 8
 Insert FC loopback cable into switch: 100000c0dd00b682, port: 8
 Continue Isolation ?
 switchtest started on switch 100000c0dd00b682 port 8
Estimated test time 14 minute(s)
01/30/02 11:25:12 diag209 Storage Automated Diagnostic Environment: MSGID
4001 switchtest.WARNING
switch0: "Maximum transfer size for a FABRIC port is 200. Changing transfer
 size 2000 to 200"
 switchtest completed successfully
 Remove FC loopback cable from switch: 100000c0dd00b682, port: 8
 Restore ORIGINAL FC Cable into switch: 100000c0dd00b682, port: 8
 Suspect ORIGINAL FC GBIC in switch: 100000c0dd00b682, port: 8
 Retest to verify FRU replacement.
 linktest completed on FC interconnect: switch to switch