Sun Microsystems 3900 Series User Manual
Chapter 8
Troubleshooting the Sun StorEdge T3+ Array Devices
111
For Internal Use Only
t3
power.
battery
battery
Alarm-
Red
Y
[ Info/Action ] The
state of
power.u1pcu1.BatStat
e on diag213
(ip=xxx.20.67.213) is
Fault
state of
power.u1pcu1.BatStat
e on diag213
(ip=xxx.20.67.213) is
Fault
Possible causes are:
1. Voltage level on
1. Voltage level on
power supply and
battery have
moved out of
acceptable
thresholds.
battery have
moved out of
acceptable
thresholds.
2. The internal PCU
temp has exceeded
acceptable
thresholds.
acceptable
thresholds.
3. A PCU fan has
failed.
Information: The state
of the batteries in the
Sun StorEdge T3+
array is not optimal.
of the batteries in the
Sun StorEdge T3+
array is not optimal.
Recommended action:
1. Telnet to the
affected Sun
StorEdge T3+
array.
StorEdge T3+
array.
2. Run
refresh -s
to verify the
battery state.
battery state.
3. Replace the
battery, if
necessary
necessary
t3
power.fan
Alarm-
Red
Y
[ Info/Action ] The
state of
power.u1pcu1.Fan1Sta
te on diag213
(ip=xxx.20.67.213) is
Fault
state of
power.u1pcu1.Fan1Sta
te on diag213
(ip=xxx.20.67.213) is
Fault
Information: The state
of a fan on the Sun
StorEdge T3+ array is
not optimal.
of a fan on the Sun
StorEdge T3+ array is
not optimal.
Recommended action:
1. Telnet to affected
Sun StorEdge T3+
array.
array.
2. Verify the fan state
with
fru stat.
3. Replace the power
cooling unit, if
necessary.
necessary.
Category
Component
EventType
Sev
Action
Description
Information