Sun Microsystems 3900 Series User Manual

Page of 162
120
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
t3
interface.
loopcard
StateChange-
Red
Y
[ Info/Action ]
Information:
The Sun StorEdge T3+
array has indicated
that the loopcard is no
longer in an optimal
state.
Recommended action:
1. Telnet to the
affected Sun
StorEdge T3+
array.
2. Verify loopcard
state with
fru
stat
3. Verify matching
firmware with
other loopcard.
4. Re-enable loopcard
if possible (enable
u(encid)|[1|2|]
5. Replace the
loopcard if
necessary.
Category
Component
EventType
Sev
Action
Description
Information