Sun Microsystems 3900 Series User Manual

Page of 162
38
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
CODE EXAMPLE 3-6
VxDMP
Error Message
To Verify the Storage Service Processor
You can check the A3/B3 FC link using the Storage Automated Diagnostic
Environment, Diagnose—Test from Topology functionality. Storage Automated
Diagnostic Environment’s implementation of diagnostic tests verify the operation of
user-selected components. Using the Topology view, you can select specific tests,
subtests, and test options.
Refer to the Storage Automated Diagnostic Environment User’s Guide for more
information.
FRU Tests Available for the A3/B3 FC Link
Segment
The
Linktest
is not available.
The switch and/or GBIC -
switchtest
test:
Can be used only in conjunction with the loopback connector.
Cannot be cabled to the virtualization engine while
switchtest
runs.
No virtualization engine tests are available at this time.
Jan
8 18:26:38 diag.xxxxx.xxx.com vxdmp: [ID 619769 kern.notice] NOTICE:
vxdmp: Path failure on 118/0x1f8
Jan
8 18:26:38 diag.xxxxx.xxx.com vxdmp: [ID 997040 kern.notice] NOTICE:
vxvm:vxdmp: disabled path 118/0x1f8 belonging to the dmpnode 231/0xd0