Sun Microsystems 3900 Series User Manual

Page of 162
44
Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002
CODE EXAMPLE 3-8
Failed Path marked “unusable”
FRU tests available for the A4/B4 FC Link
Segment
The
switchtest
can only be run from the Storage Service Processor
The
linktest
will be able to isolate the switch and the GBIC on the switch. It
will not be able to isolate the cable or the Sun StorEdge T3+ array controller.
To Isolate the A4/B4 FC Link
1. Quiesce the I/O on the A4/B4 FC link path.
2. Run
linktest
from the Storage Automated Diagnostic Environment GUI to
isolate suspected failing components.
Alternatively, follow these steps:
1. Quiesce the I/O on the A4/B4 FC link path.
2. Run
switchtest
to test the entire link (re-create the problem).
3. Break the connnection by uncabling the link.
4. Insert the loopback connector into the switch port.
# cfgadm -al
Ap_Id
Type
Receptacle
Occupant
Condition
ac0:bank0                      memory       connected    configured   ok
ac0:bank1
memory
empty
unconfigured unknown
c1
scsi-bus
connected
configured
unknown
c16
scsi-bus
connected
unconfigured unknown
c18
scsi-bus
connected
unconfigured unknown
c19
scsi-bus
connected
unconfigured unknown
c1::dsk/c1t6d0
CD-ROM
connected
configured
unknown
c20
fc-private
connected
unconfigured unknown
c21
fc-fabric
connected
configured
unknown
c21::50020f2300006355
disk
connected
configured
unusable