Sony 2 User Manual

Page of 362
273
Setup Relating to DCU
  
Ch
apt
er 16 
E
ngin
eering Se
tup
Serial Port Settings (Serial Port Assign Menu)
To set the protocol to match a device connected to a 9-pin serial port, display 
the DCU>Serial Port Assign menu.
To display the Serial Port Assign menu
In Engineering Setup, select VF5 ‘DCU’ and HF5 ‘Serial Port Assign.’
The serial port setting status appears in the status area.
Making serial port settings
Use the following procedure.
1
In the DCU>Serial Port Assign menu, select the target for the setting 
(DCU1 or DCU2) from the <DCU Select> group.
2
Using any of the following methods, select the serial port.
• Press directly on the list on the left of the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob to make the selection.
a) The setting value range depends on the DCU port setting.
3
Using any of the following methods, select the protocol for the connected 
device.
• Press directly on the list on the right of the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob to make the selection.
a) 1. No Assign: nothing is connected to the serial port.
2. P-Bus: P-Bus device.
3. VTR: VTR
4. DDR SD9P: disk recorder (Sony disk 9-pin protocol)
4
Press [Device Type Set].
The selected protocol is reflected on the left of the status area.
Knob Parameter
Adjustment
Setting 
values
1
Port No
Serial port
1 to max. 
a)
Knob Parameter
Adjustment
Setting 
values
2
Device Type
Protocol selection
1 to 4 
a)