Wiring Settings (Wiring Menu)
When configuring a system in which the switcher inputs and outputs are 
connected to a router, it is necessary to set this connection configuration 
(referred to as “wiring”) in the S-Bus space.
To make the wiring settings, use the Router/Tally>Wiring menu. The settings 
are common to the parallel and serial tallies.
To display the Wiring menu
In the Engineering Setup menu, select VF6 ‘Router/Tally’ and HF3 ‘Wiring.’
The status area shows the wiring settings.
Making new wiring settings
Use the following procedure.
1
In the Router/Tally>Wiring menu, press [New].
The New menu appears.
2
With a knob or menu operation, set the destination.
When switcher inputs and outputs are connected to the router in a group, 
you can specify the start and end destination addresses.
Destination From: Specify the start destination address for the wiring 
configuration.
Destination To: When the wiring configuration is multiple, specify the 
end destination address. For a single wiring connection, this setting is 
not required.
Destination Level: Specify the destination level of the wiring 
configuration.
Knob
Parameter
Adjustment
Setting values
1
Destination (From)
Destination start address 1 to 1024
2
Destination (To)
Destination end address
From start address to 
1024
3
Destination (Level)
Destination level
1 to 8