Shindaiwa 81188 User Manual

Page of 40
6
Figure 9
Cutting Attachment Shield
Install the Cutting Attachment Shield 
C3410.
1.  Insert the cutting attachment shield 
between the outer tube and the cutting 
attachment mounting plate. 
See Figure 9.
 
  WARNING!
NEVER operate the unit without the 
cutting attachment shield installed 
and tightly secured!
CAUTION!
Make sure the clamp screw and 
retaining nut are securely tightened 
before tightening the four socket-head 
cap screws
.
NOTE:
It may be necessary to loosen the retaining 
nut and clamp screw to adjust cutting attach-
ment shield mounting plate.
2.  Fit the two shims and the bracket over 
the outer tube and loosely install the 
four socket-head screws. See Figure 9.
3.  Tighten the four socket-head cap screws 
to secure the cutting attachment shield.
Assembly
Sub-Shield C3410. 
(when trimmer head is in use)
1.  Attach the shield extension to the  
cutting attachment shield. See figure 9B.
 
  WARNING!
NEVER use  this machine without 
sub-shield when using a trimmer 
head.
CAUTION!
Make sure the sub-guard is  
completely hooked at the hook  
receiver.
Sub-shield
Hook
Hook
Receiver
Cutting Attachment Shield
Outer 
Tube
Socket-
Head Cap 
Screw
Clamp Screw
Retaining 
Nut
Cutting  
Attachment Mounting  
Plate
Shim
Shim
Bracket
Cutting 
Attachment 
Shield
Line Cutter
Figure 9A
Cutting Attachment Shield
Sub-shield with 
Line Cutter
Figure 9B